Alarm Recording; Pre-Alarm Recording - Sanyo DSR-5016 Instruction Manual

Digital video recorder with multiplexer function
Hide thumbs Also See for DSR-5016:
Table of Contents

Advertisement

3
RECORDING
FULL indicator

Alarm recording

Use the following procedure to record alarm video when an
alarm signal is detected.
1
Set alarm recording. ( P.93)
2
When an alarm signal is detected
When an alarm signal is detected, "ALARM" flashes in the
operation display and alarm recording starts (indicated by
"REC".)
Whenever an alarm occurs, the number of alarms
indicated in the operation display is incremented.
01-01-05 00:00:00 REC REPEAT EN A ALARM 0000001
02
If an alarm occurs during normal recording or timer
recording, recording ends.
A maximum of 1,000,000 alarm recordings can be made
on one hard disk. The number of maximum recordings can
be increased to 6,000,000 by expanding the optional hard
disk. However, the maximum number of recordings is
affected by set recording conditions. Be sure to check the
menu settings and display content.
3
End alarm recording.
When the alarm duration has expired (default setting: 20
seconds), both "REC" and "ALARM" stop flashing on the
operation display and recording stops.
Be sure to set the time when using the digital video
recorder for the first time. Recording is not possible until
the time is set. ( P.20)
When alarm recording total exceeds 1,000,000 and
"OVERWRITE" on the <RECORDING CONDITIONS SET>
screen ( P.80) is set to "ON", older recordings are
overwritten even if the hard disk has remaining memory
capacity.
Alarm recording is not performed when "OFF" is set.
Use the following procedure to record video immediately
before the occurrence of an alarm.
1
Counts the number of
"PRE" appears in the operation display. Pre-alarm recording
alarms.
starts (without the "REC" symbol being displayed).
Displays up to
9999999.
2
After 9999999, the
counter returns to
Pre-alarm recording is automatically ended and alarm
0000000 and
recording starts.
resumes counting
from 1.
30
When "OVERWRITE" on the <RECORDING
CONDITIONS SET> screen is set to "OFF" and the space
remaining in the recording area becomes insufficient, the
FULL indicator begins to flash. If recording is continued
beyond this point, the recording area becomes full and
recording stops. Perform AREA FULL RESET to enable
recording. ( P.79)

Pre-alarm recording

Set pre-alarm recording. ( P.96)
If an alarm is detected
"PRE" disappears from the operation display and "ALARM"
begins to flash.
01-01-05 00:00:00 REC REPEAT EN A ALARM 0000001
02
When recording for the first time, the default settings are
used. The image quality and recording rate can be
changed. ( P.97)
When "OVERWRITE" on the <RECORDING
CONDITIONS SET> screen is set to "OFF" and the space
remaining in the recording area becomes insufficient, the
FULL indicator begins to flash. If recording is continued
beyond this point, the recording area becomes full and
recording stops. Perform AREA FULL RESET to enable
recording. ( P.79)
English

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsr-5009pDsr-5016p

Table of Contents