Baxi Bioflo Installation & Servicing Instructions Manual page 29

Pellet central heating system boiler
Table of Contents

Advertisement

For the Service Technician
Air intake/exhaust flap
Factory setting:
Control
Operating time in s 300
Setting range:
The set operating time should be twice as long as the actual opera-
ting time of the air intake/exhaust flap.
Limits for blower speed
Factory setting:
rpm
Setting range:
rpm
Step width:
rpm
Display module installation
This is not required for the BAXI Bioflo.
Language
Selection of „Language" for the display texts on InfoWIN.
OFF
30 – 600 s
minimum
maximum
1250
2050
1150–1450 1950–2250
50
29
Air intake/exh. flap
Control
Operating time in s 300
Fig. 45
Choose
Back
Limits for
blower speed
minimum
1250
maximum
2050
Fig. 46
Choose
Back
Install
display module
Start installation
procedure
Fig. 47
Choose
Back
Language
Deutsch
English
Français
Italiano
Castellano
Choose
Back
Fig. 48
OFF