For the Electrician
Electrical power supply 230 VAC (mains plug) and electrical connections:
Electrical power supply 230 VAC (mains power plug) and the control panel with all electrical connections are
located behind the right side panel cladding. The mains plug, safety thermostats and fuse are located on the
outside of the control panel. The control panel includes the main board and the connection terminals (screw-
less spring-type terminal) – Fig. 27.
Mains power plug
(230 VAC)
Cover of safety thermostat
auger tube
Control panel
Fig. 27
Control panel
Electrical cables must not touch heating and exhaust pipes, nor must they come in contact with non-
insulated boiler components. They are to be sufficiently braced and provided with a protective tube.
To access the control panel:
– The rear right side panel must be unhooked and removed upwards.
– Disconnect the mains power plug and remove the screw behind it – Fig. 28.
Mains power plug
(230 VAC)
Fig. 28
Disconnecting the mains power
plug and removing the screw.
Fig. 29
Cable feed-throughs – rear view