Intel® Server Board S2600CP Connector/Header Locations and Pin-outs
7.3.4
SAS Connectors
The server board includes eight SAS/SATA connectors. By default, only the connectors labeled
from "SAS_0" to "SAS_3" are enabled and support transfer rates of up to 3Gb/s. The
connectors labeled from "SAS_4" to "SAS_7" are only enabled when an optional Intel
C600 Upgrade Key is installed. The following tables provide the pin-out for each connector.
7.3.5
SAS SGPIO Connectors
Pin
1
3
5
7.3.6
Intel
RAID C600 Upgrade
®
The server board provides one connector to support Intel
RAID C600 Upgrade Key is a small PCB board that enables different versions of RAID 5
software stack and/or upgrade from SATA to SAS storage functionality. The pin configuration of
connector is identical and defined in the following table.
Table 37. Intel
90
Table 34. SATA SGPIO Connector Pin-out
Pin
1
SCLK
2
SLOAD
3
GND
4
SDATAOUT0
5
SDATAOUT1
Table 35. SAS/SATA Connector Pin-out
Pin
1
GND
2
SATA_TX_P
3
SATA_TX_N
4
GND
5
SATA_RX_N
6
SATA_RX_P
7
GND
Table 36. SAS SGPIO Connector Pin-out
Signal Name
CLOCK
GND
DATAIN
Key Connector
®
RAID C600 Upgrade Key Connector Pin-out
Pin
1
GND
2
FM_PBG_DYN_SKU_KEY
3
GND
4
FM_SSB_SAS_SATA_RAID_KEY
Intel order number G26942-003
Intel
Server Board S2600CP and Server System P4000CP TPS
®
Signal Name
Signal Name
Pin
Signal Name
2
LOAD
4
DATAOUT
®
RAID C600 Upgrade Key. The Intel
Signal Name
®
RAID
®
Revision 1.1