B.3.7 Double-Shield Termination Technique - Method C.1
In rare situations where double shielding may be necessary, the outer shield should be grounded at both
ends, while the inner shield should be grounded only at one end.
All other restrictions set forth for in Table B-8 are applicable.
The maximum length of the braids should be approximately 4 inches.
Figure B-12. Method C.1 Double-Shield Termination
Table B-8. Shielded Cable Preparations for Garmin Connectors
Number of
Backshell
Pins
Size
Std/HD
1
9/15
2
15/26
3
25/44
4
37/62
5
50/78
Page B-16
Revision A
NOTE
Float Min
Float Max
(inches)
(inches)
1.25
2.25
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
Window
Ideal Float
Min
(inches)
(inches)
1.75
2.75
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
G3X Installation Manual – Appendix B
Window
Max
(inches)
5.25
5.5
5.5
5.5
5.5
190-01115-01