Figure B-8 Method C.1 Double-Shield Termination; Table B-5 Shielded Cable Preparations For Garmin Connectors - Garmin GDU 37X Installation Manual

Hide thumbs Also See for GDU 37X:
Table of Contents

Advertisement

B.1.7 Double-Shield Termination Technique - Method C.1
In rare situations where double shielding may be necessary, the outer shield should be grounded at both
ends, while the inner shield should be grounded only at one end.
All other restrictions set forth for in Table B-5 are applicable.
NOTE
The maximum length of the braids should be approximately 4 inches.

Figure B-8 Method C.1 Double-Shield Termination

Table B-5 Shielded Cable Preparations for Garmin Connectors

Number of
Backshell
Pins Std/
Size
HD
1
9/15
2
15/26
3
25/44
4
37/62
5
50/78
190-01054-01
Rev. D
Float Min
Float Max
(inches)
(inches)
1.25
2.25
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
Window
Ideal Float
Min
(inches)
(inches)
1.75
2.75
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
GDU 37X Installation Manual
Window
Max
(inches)
5.25
5.5
5.5
5.5
5.5
Page B-12