Motorola 110502USM001 - Vanguard 60 Router User Manual page 71

User guide
Table of Contents

Advertisement

Configuring a Vanguard Router
T0100-01, Revision B
Remote Connection ID
Range:
1
Default:
1
Description:
When the LAN Connection Record sends a call request, this
parameter specifies which target WAN Adapter LAN Connection
Table to connect to.
The Remote Connection ID is carried in the Call User Data (CUD)
field of the call request packet when Encapsulation Type = CODEX.
Boot Type:
Changes to this parameter require a Table and Node Record boot.
Guidelines:
Appears only with:
• CODEX or RFC 1294 encapsulation
• Autocall mnemonic entered
*Parallel SVCs
Range:
0 to 1
Default:
0
Description:
Specifies the maximum number of parallel connections that can be
established to the remote destination. Parallel SVCs are established
when congestion thresholds are reached on active connections.
Boot Type:
Changes to this parameter require a Table and Node Record boot.
Guidelines:
Appears only if:
• LAN Forwarder Type is configured as ROUT/BROUT
• An Autocall Mnemonic name has been specified
• Encapsulation Type is either RFC 877 or CODEX
Parallel SVC Trigger Mechanism:
Range:
THRESHOLD, PORT_CONGEST
Default:
THRESHOLD
Description:
Specifies which criterion is used to activate or deactivate parallel
SVCs.
• THRESHOLD - The length of the queue at the LAN-WAN
interface determines when to bring up a second link.
• PORT_CONGESTION - The port utilization is compared to the
configured thresholds to determine when to activate or
deactivate a second link.
Guidelines:
If using the PORT_CONGEST value, you must configure the
Network Services BoD Table parameters.
Configure LAN Connections
Release 5.4
3-21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vanguard 100Vanguard 200Vanguard 6520Vanguard 6560

Table of Contents