Furuno DS-80 Operator's Manual page 16

Doppler speed log marine speed and distance measuring equipment (sdme)
Hide thumbs Also See for DS-80:
Table of Contents

Advertisement

MENU
DISTANCE RUN DISPLAY
DEMO
SYSTEM MENU
SYSTEM MENU2
2. Press the Omnipad at
DISTANCE RUN DISPLAY and press
the [ENT] key.
DISTANCE RUN DISPLAY
DATA DISPLAY
CONTACT CLOSURE
RESET
SET
3. Select DATA DISPLAY and press the
[ENT] key.
DISTANCE RUN DISPLAY
DATA DISPLAY
CONTACT CLOSURE
RESET
IEC61162(VLW)
SET
CONTACT CLOSURE
4. Press
to select IEC 61162(VLW)
and press the [ENT] key.
5. Press the [MENU] key twice to close the
menu.
1.6.2 Adjusting distance run
Distance run can be changed when the
menu item DATA DISPLAY is selected to
CONTACT CLOSURE. It may also be
changed only at the display unit when IEC
61162(VLW) is selected. .
1. Press the [MENU] key to open the
menu.
2. Use
to select DISTANCE RUN
DISPLAY and press the [ENT] key.
3. Select SET and press the [ENT] key.
to select
OFF
0.00nm
ENT SET
OFF
0 . 0 0 nm
ENT
SET
The cursor circumscribes the leftmost
digit of the distance run figure.
DISTANCE RUN DISPLAY
DATA DISPLAY
RESET
SET
Cursor
4. Press the Omnipad at
the digit to change.
5. Press the Omnipad at
change value. The setting range is 0.00
nm to 999999.99 nm.
6. Press the [ENT] key followed by
pressing the [MENU] key twice to
conclude your selection and close the
menu.
1.6.3 Resetting distance run to zero
Distance run can be reset to zero when the
menu item DATA DISPLAY is selected to
CONTACT CLOSURE. It may also be reset
to zero only at the display unit when IEC
61162(VLW) is selected.
1. Press the [MENU] key to open the
menu.
2. Press the Omnipad at
DISTANCE RUN DISPLAY and press
the [ENT] key.
3. Select RESET and press the [ENT] key.
DISTANCE RUN DISPLAY
DATA DISPLAY
CONTACT CLOSURE
RESET
SET
4. Press the Omnipad at
8
CONTACT CLOSURE
OFF
000000.00nm
ENT SET
or
to select
or
to
to select
OFF
OFF
ON
to select ON.

Hide quick links: