Troubleshooting - Furuno DS-80 Operator's Manual

Doppler speed log marine speed and distance measuring equipment (sdme)
Hide thumbs Also See for DS-80:
Table of Contents

Advertisement

3.2

Troubleshooting

This section provides troubleshooting procedures. Advanced level troubleshooting should
be done by referring to the Service Manual (optional supply).
Problem
General
Cannot turn on the
power.
Power is on but
nothing appears on
the screen.
Doppler speed indication
Last correct speed is displayed
STW
SPEED
10.0
(display freezes).
kt
DISTANCE
12.50
Reverse video and blinking
nm
SPEED
STW
Speed shown as "**.*".
**. *
kt
DISTANCE
12.50
nm
SPEED
STW
10.0
kt
DISTANCE
12.50
nm
GPS speed indication
SPEED
GPS
Speed indication shown as "**.*".
**.*
kt
DISTANCE
12.50
nm
----
SPEED
"GPS" is replaced with "----".
---
kt
DISTANCE
12.50
nm
If any abnormal speed indication continues
contact your dealer for advice.
Probable cause
Loosened power cable
Blown fuse
Contrast too low.
STW
flashing
Fasten the power cable.
Replace the fuse.
Press the [*] key several times.
Ship's speed cannot be calculated
because of air bubbles, etc. (Speed error :
30 seconds)
Problem with the transducer or air
bubbles.
Speed error continues more than 30
seconds.
Temperature sensor is abnormal.
GPS data error.
No GPS data for 30 seconds.
GPS receiver disconnected.