6.2

Fuse Replacement

A fuse is in the fuse holder on the power cable and inside the power supply unit, and they protect
the equipment from reverse polarity of the ship's mains and equipment fault. If a fuse blows, find
out the cause before replacing it. Use the correct fuse. Using the wrong fuse will damage the
equipment and void the warranty.
Unit
DIsplay unit
(fitted on power
cable)
Power supply unit
(for FR-8252)
6.3

Magnetron Life

When the magnetron (generates microwaves) has expired, distant targets cannot be seen on the
display. When you feel that long range performance has decreased, contact a FURUNO agent or
dealer about replacement of the magnetron.
Model
Magnetron type
FR-8062
MAF1422B
MG4006
FR-8122
MAF1425B
FR-8252
M1458F
6.4

LCD Backlight Life

The life of the LCD backlight, which provides illumination for the LCD, is approximately 4,300
hours. The display brilliance cannot be raised when the backlight has worn out. Have a qualified
technician replace the backlight when brilliance cannot be raised.
Part
Lamp holder complete set
WARNING
Use the proper fuse.
Use of a wrong fuse can result in damage
to the equipment or cause fire.
Unit and fuses
Type
FGBO 15A AC125V
FGBO 10A AC125V
FGBO 15A AC125V
FGBO 7A AC125V
Model and magnetron
Code no.
000-146-871
000-158-788-10
000-150-838
000-158-790-10
000-158-780-10 Approx 1,000 hours
Type No.
121LHS18
6. MAINTENANCE & TROUBLESHOOTING
Code No.
000-549-014
12 VDC
000-549-065
24 VDC
000-549-014
12 VDC
000-549-013
24 VDC
Estimated life
Approx. 3,000 hours
Code No.
000-158-827-10
Remarks
6-3