Display Fault/Error Codes; Diagnostic Tests - Maytag MED / GD 9700S Technical Education

Front-loading gas and electric dryers
Table of Contents

Advertisement

DISPLAY FAULT/ERROR CODES

DISPLAY DESCRIPTION
PF
Power failure
Thermistor
E1
open
Thermistor
E2
shorted
User
interface or
E3
software
mismatch

DIAGNOSTIC TESTS

These tests allow factory or service personnel
to test and verify all inputs to the electronic
control board. It would be a good idea to per-
form a quick, overall checkup of the dryer with
these tests before going to any specific trouble-
shooting tests.
Activating The Diagnostic Test Mode
1.
Be sure the dryer is in the Standby Mode
(plugged in and all indicators off).
2.
Press the following button sequence within
5 seconds of power up:
+ (more time)
– (less time)
+ (more time)
– (less time)
3.
If this test mode has been entered suc-
cessfully, all indicators on the console are
illuminated, with "88" showing in the "Esti-
mated Time Remaining" (2-digit) display.
EXPLANATION AND RECOMMENDED PROCEDURE
"PF" flashes to indicate that a power failure occurred while
the dryer was running. Press HOLD TO START to continue
the cycle, or press OFF/Pause to clear the display.
"E1" flashes if the thermistor is open. See TEST #3a.
"E2" flashes if the thermistor has shorted. See TEST #3a.
"E3" flashes when there is a keyswitch or software
mismatch. This error code will ONLY appear when in the
Diagnostic Test mode. See TEST #5.
If the entry into the diagnostic mode was un-
successful, take the following actions for spe-
cific indications:
Indication 1: None of the indicators or display
turns on.
Action: Select any Manual Cycle. If the indi-
cators turn on, then try to change the dryer
time by pressing the + and – buttons. If either
button fails to change the time, something is
faulty with one of those buttons, and it is not
possible to enter the diagnostic mode. Remove
the console electronics and housing. If no in-
dicators come on after pressing the Manual
Cycle buttons, go to TEST #1 (Supply Con-
nections) on page 6-4.
Indication 2: E1 or E2 flashes on the display.
Action: Proceed to TEST #3a (Thermistor
Test) on page 6-8.
Indication 3: E3 flashes on the display.
Action: Check to make sure that the correct
electronic control board, console electronics,
and housing are installed.
6-2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Med / gd 9600sEpic med/gd9700sEpic med/gd9600s

Table of Contents