Diagnostic Codes; Display Fault/Error Codes - Maytag MDE9700A Series Technical Information

27” electric dryer
Hide thumbs Also See for MDE9700A Series:

Advertisement

Troubleshooting
To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless
testing requires power.
opposite direction, the more recent code will be
displayed.
While a diagnostic code is displayed, if the Start/Pause
button in the center of the Rotary Cycle Selector is
pressed and held, the machine will display the number of
cycles ago the diagnostic code occurred. When the
Start/Pause button is released, the diagnostic code is
again displayed.
Clearing Diagnostic Codes
To clear the diagnostic code list press the Sensor Dry
Level and Time keypads together for 3 seconds while
viewing the list. The cycle count for each diagnostic code
will be reset to 0, but not the machine cycle count.

Diagnostic Codes

Code
Description
Dryer
1
Thermistor
Short Sensed
Thermistor
2
Open Sensed
Door Circuit
3
Failure
Possible motor
4
transistor error
16026116 Rev. 0
!
Trigger
Action Taken
The
Check for:
Thermistor
- Clogged lint
resistance is
screen.
very low.
- Restricted vent
system.
- Check Thermistor
resistance.
The
Check for:
Thermistor
Low ambient
resistance is
temperature in
very high
room (Below
°
°
-22
F/-30
C).
- Outside vent
damper is stuck
open in
wintertime.
- Loose or open
wire terminals.
- Check Thermistor
resistance.
Invalid state
Check for:
for more
- Loose or open
than 256
wire terminals in
milliseconds
Door Sense
circuit.
If either
Check for:
motor
- Loose
transistor is
connections in
seen open
motor circuit.
or shorted
- Run System
during
Check Mode and
startup
check the motor
relay function.
- If relay functions,
disregard the
diagnostic code.
- If relay does not
function, replace
machine control
board.
WARNING
Code
Description
Stuck Key
8
No Wet Clothes
10

Display Fault/Error Codes

Disp Description
tS
Dryer
Thermistor
Short Sensed
do
Door Open
FE
Power source
frequency error
dC
Door Circuit
Failure
Heater Error
hE
4
Trigger
Action Taken
A key is
Run membrane pad
sensed to be
check and replace
pressed
console
more than
w/membrane pad if
75 seconds,
necessary.
the key is
assumed to
be stuck.
Sensor bar
Check for:
detects no
- Running dryer with
wet clothes
no wet clothes in
while a
sensor dry cycle
Sensor Dry
Cycle
Trigger
Action Taken
The Thermistor
Check for:
resistance is very
- Clogged lint
low.
screen.
- Restricted vent
system.
- Check Thermistor
resistance.
- Check for
diagnostic code 1
Running the dryer
Check for:
with door open
- Close the door,
and run the dryer
- Loose or open
wire terminals in
Door Sense
circuit.
- Check for
diagnostic code 3
Invalid power
Check for:
source frequency
- Not using regular
power source
frequency
- Invalid power
frequency sense
circuit
Invalid state for
Check for:
more than 256
- Loose or open
milliseconds
wire terminals in
Door Sense
circuit.
- Check for
diagnostic code 3
Invalid heating
Check for:
temperature in
- Restricted vent
running the dryer
system.
- Check Thermistor
resistance.
March 2005