Safety Label; Serial No. Decal - Regency C34 Classic Owners & Installation Manual

Direct vent freestanding gas stove
Hide thumbs Also See for C34 Classic:
Table of Contents

Advertisement

SAFETY LABEL

This is a copy of the label that accompanies
each CLASSIC Direct Vent Freestanding Gas
Stove. We have printed a copy of the contents
here for your review. The safety label is located
on the back panel.
Listed:
VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION
Certified for/Certifi e pour:
Tested to:
CGA-2-17-M91, ANSI Z21.88a-2007 / CSA 2.33a-2007
WN# 16477
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
NATURAL GAS STOVE:
L
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
PROPANE GAS STOVE:
L
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation
Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations
Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where
not prohibited by local codes. See owner's manual for details.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1
en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured
Home Construction and Safety Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations
Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U.
seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec
d'autres gaz sauf si une trousse de conversion certifiée est fournie.
This vented gas fireplace heater is not for use with air filters.
For use with glass doors certified with the appliance only
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.
FOYER AU GAZ À ÉVACUATION -
6
é
CANADA and U.S.A.
Model C34-NG3
P
APPAREIL FONCTIONNANT AU
L
CONCU POUR ETRE POELE:
5"
WC (1.25kpa)
Pression d'allimentation minimum
3.8" WC (0.94kpa)
Pression à la tubulure d' chappement lev e
1.1" WC (0.27kpa)
Pression à la tubulure d' chappement basse
#36
(2.71mm)
Grandeur de l'injecteur
16000 BTUH (4.69 kw/h)
D bit
é
Calorifique
32000 BTUH (9.38 kw/h)
D bit Calorifique maximum selon
é
0-4500 ft/pi (0-1372m)
l'altitude
Model C34-LP3
P
APPAREIL FONCTIONNANT AU PROPANE
L
CONCU POUR ETRE POELE:
12" WC (2.98 kpa)
Pression d'allimentation minimum
11" WC (2.73 kpa)
Pression à la tubulure d' chappement lev e
2.9" WC (0.72 kpa)
Pression à la tubulure d' chappement basse
#52
(1.61mm)
Grandeur de l'injecteur
16000 BTUH (4.69 kw/h)
D bit
é
Calorifique
32000 BTUH (9.38 kw/h)
D bit
é
Calorifique
0-4500 ft/pi (0-1372m)
l'altitude
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil
NE PAS UTILISER AVEC DUCOMBUSTIBLE SOLIDE.
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
GAZ
NATURAL
Modéle C34-NG3
é
é
é
é
minimum selon
Modéle C34-LP3
é
é
é
é
minimum selon
maximum selon
Regency
®
NOTE: Regency
units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.
DUPLICATE SERIAL NO.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
Serial No./ No de serie
Minimum Clearances to Combustibles /
Degagement Minimum
De Materiaux Combustibles
Back wall
Back wall
E
Minimum ceiling height from
top of unit:36"/914mm
Minimum plafond hauteur en
haut de l'appareil: 36"/914mm
Minimum clearance to vent 1.25"/32mm
DOOR SEAL:
Please check that the door is properly sealed.
Electrical supply / Électrique 115VAC, 1.13 A, 60Hz.
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Made in Canada/
Fabrique au Canada
®
CLASSIC C34-3 Direct Vent Freestanding Gas Stove
297
297
A 10"/250mm
B 6"/150mm
E 1.5"/38mm
918-490a