Door Handle; Remote Control Installation; Remote Wall Switch; Wall Thermostat - Regency C34 Classic Owners & Installation Manual

Direct vent freestanding gas stove
Hide thumbs Also See for C34 Classic:
Table of Contents

Advertisement

DOOR HANDLE

Attach spring handle by rotating counter clock-
wise onto rod. Ensure that the spring fi ts into
the entire length of the rod.
DO NOT TRY TO TURN
DOOR HANDLE!
IT IS NOT DESIGNED
TO BE MOVED.
REMOTE CONTROL
INSTALLATION
®
Use the Regency
Remote Control Kit approved
for this unit. Use of other systems may void
your warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.
1) Choose a convenient location on the wall
to install the receiver (protection from ex-
treme heat is very important). Run wires
from the fi replace to that location. Use the
Thermostat Wire Table.
2) Connect the two wires to the gas valve. See
diagram below.
®
Regency
CLASSIC C34-3 Direct Vent Freestanding Gas Stove
CAUTION
Do not wire millivolt remote con-
trol wires to the
120V AC wires
3) Install 3 AAA alkaline batteries in transmitter
and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the
remote receiver to "remote"
mode. The remote control is now ready for
operation.
REMOTE
WALL SWITCH
1) Run the wire through the opening in the rear
of the unit. Be careful not to damage any
wires.
Note: We recommend a maximum of 15' of
wire but if you wish to go with a longer
run use the Thermostat Wire Table.
2) Connect the wire to the wall switch and install
into receptacle box.
CAUTION
Do not wire millivolt wall switch
for gas appliance to the 120V AC
wires

WALL THERMOSTAT

INSTALLATION
Regency
®
offers an optional programmable
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.
Connect the wires as per the wiring diagram.
Use the Thermostat Wire Table to determine the
maximum wire length.
INSTALLATION
CAUTION
Do not wire millivolt wall thermo-
stat wires to the 120V AC wires
Note: Preferable if the thermostat is in-
stalled on an interior wall.
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
50 Ft.
16 GA.
32 Ft.
18 GA.
20 Ft.
20 GA.
12 Ft.
22 GA.
9 Ft.

FINAL CHECK

Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly. This includes:
1) Clocking the appliance to ensure the cor-
rect fi ring rate (rate noted on label) at 15
minutes.
2) If required, adjusting the primary air to ensure
that the fl ame does not carbon. First allow
the unit to burn for 15 min. to stabilize.
3) Check for proper draft.
CAUTION
Any alteration to the product that causes
sooting or carboning that results in dam-
age to the unit is not the responsibility of
the manufacturer and will not be covered
by the warranty.