INSTALLATION

VENTING ARRANGEMENTS

HORIZONTAL TERMINATIONS FOR
ALL VENTING SYSTEMS
The shaded areas in the diagram below show all allowable combi-
nations of vertical runs with horizontal term-inations. Maximum
one 90
O
elbow (two 45
o
elbows equal one 90
Propane and Natural Gas: Residential, Manufactured
and Mobile Homes Installations
The venting arrangements diagrammed below, have a min. of 75% (fl ue
loss) effi ciency with Fan Off, as required for manufactured homes. (Actual
effi ciency may be as high as 85%)
May be installed in Manufactured (Mobile) Homes after fi rst sale.
NOTE: See "Vent Restrictor Position" section for installation instructions for the Vent Restrictor Position.
Example A)
Venting has a horizontal termination.
A 7 ft. vertical run with 6 ft. horizontal run does not fall within the shaded area, and therefore is an allowable installation with
the factory set vent restrictor position of "C".
Example B)
Offset to Vertical Vent.
A 15 ft. vertical run with 4 ft. horizontal offset distance falls within the shaded area and is an allowable installation with Vent
Restrictor Position "R" (Right).
18
VERTICAL TERMINATION SYSTEMS
FOR RESIDENTIAL MANUFACTURED
The shaded area in the diagram below shows all allowable combi-
o
elbow).
nations of straight vertical and offset to vertical runs with vertical
terminations. Maximum two 45
All vertical and offset to vertical vent installations require Vent Restrictor
Position "R" (Right). If the vent is ENCLOSED in a chase (min. size 9" x
9") maintain a 1-1/4" clearance to combustibles.
May be installed in Manufactured (Mobile) Homes after fi rst sale.
Venting Arrangements Examples:
VENTING ARRANGEMENTS
AND MOBILE HOMES
o
elbows.
Straight Vertical and Offset to Vertical Terminations
use Vent Restrictor Position "R" (Right)
®
Regency
CLASSIC C34-3 Direct Vent Freestanding Gas Stove

Hide quick links: