Safety Label - Regency C33 Classic Owners & Installation Manual

Freestanding gas stove
Hide thumbs Also See for C33 Classic:
Table of Contents

Advertisement

SAFETY LABEL

This is a copy of the label that accompanies
each CLASSIC Freestanding Gas Stove - Nat-
ural Gas. We have printed a copy of the
contents here for your review. The safety label
is located on the back panel.
NOTE: Regency units are constantly being
improved. Check the label on the unit and if there
is a difference, the label on the unit is the correct
one.
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, flexible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
4
Duplicate
201
Serial No.
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Serial No.
201
Listed: VENTED GAS FIREPLACE HEATER
Certified for:
CANADA and USA
Report No.
476-1345-00 (Oct. 1996)
Tested to: ANSI Z21.88b-2003/CSA 2.33b-2003,
CAN/CGA-2.17-M91
FACTORY EQUIPPED FOR NATURAL GAS:
Model C33-NG2
Factory Equipped for 0-2000 ft.
Minimum supply pressure 5"
Manifold pressure High
3.8"
Manifold pressure Low
1.1"
Orifice size
36
Altitude
0-2000 ft/pi
Maximum Input
33,000 BTUH
Minimum Input
17,000 BTUH
HIGH ALTITUDE CONVERTED NATURAL GAS:
Model C33-NG2
Field Convertable for Altitude 2000-4500 ft.
Minimum supply pressure 5"
Manifold pressure High
3.8"
Manifold pressure Low
1.1"
Orifice size
38
Altitude
2000-4500 ft/pi
Maximum Input
29,000 BTUH
Minimum Input
15,300 BTUH
This appliance must be installed in accordance with
local codes, if any; if none, follow the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and
Propane Installation Codes, CSA B149.1.
FOR USE WITH GLASS DOORS CERTIFIED
WITH APPLIANCE ONLY.
This vented gas fireplace heater is
not for use with air filters.
Not for use with solid fuel.
Electrical Supply (115 V, 1.13A, 60 Hz)
Optional Fan: (Part #490-917)
Minimum Clearances to Combustibles
Back wall
B
A
A
A - 10"
B - 6"
Minimum ceiling height from top of unit: 36"/914mm
DO NOT REMOVE THIS LABEL
Made in Canada
Regency CLASSIC C33-2 Freestanding Gas Stove
WC/C.E. (1.25Kpa)
WC/C.E. (0.94Kpa)
WC/C.E. (0.27Kpa)
DMS
(0-610 m)
(9.67Kw/h)
(4.98Kw/h)
WC/C.E. (1.25Kpa)
WC/C.E. (0.94Kpa)
WC/C.E. (0.27Kpa)
DMS
(610-1370m)
(8.5Kw/h)
(4.48Kw/h)
Back wall
E
E - 1.5"
908-634b

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C33-ng2C33-lp2

Table of Contents