Frymaster GEN II LOVTM BIELA14 Operator's Manual page 73

Gen ii electric fryer
Hide thumbs Also See for GEN II LOVTM BIELA14:
Table of Contents

Advertisement

7.2.5 Bulk Oil System Problems
Problem
JIB won't fill.
JIB or vat filling slow.
Frypot won't fill.
7.2.6 Error Log Codes
Code
ERROR MESSAGE
E01
REMOVE DISCARD (Right)
E02
REMOVE DISCARD (Left)
E03
ERROR TEMP PROBE FAILURE
E04
HI 2 BAD
E05
HOT HI 1
E06
HEATING FAILURE
E07
ERROR MIB SOFTWARE
E08
ERROR ATO BOARD
E09
ERROR PUMP NOT FILLING
E10
ERROR DRAIN VALVE NOT OPEN
E11
ERROR DRAIN VALVE NOT CLOSED
Probable Causes
A. Incorrect setup procedure.
B. Another function is in process.
C. Dispose valve not completely closed.
D. Bulk oil tank is empty.
E. Solenoid, pump or switch issue.
A. Pump or line issues beyond the scope
of operator troubleshooting.
A. Incorrect setup procedure.
B. Dispose valve not completely closed.
C. Bulk oil tank is empty.
D. RTI pump issue.
Corrective Action
A. Power cycle fryer by disconnecting
and reconnecting 5-pin control
power cord.
B. If a filtration or any other filter
menu function is in process or
FILTER
CONFIRM YES/NO, or SKIM
VAT are displayed, wait until the
process is complete and try again.
C. Ensure the dispose valve handle is
pushed fully closed.
D. Call your bulk oil provider.
E. Call you ASA for assistance.
A. Contact your bulk oil provider.
A. Power cycle fryer by disconnecting
and reconnecting 5-pin control
power cord.
B. Ensure the dispose valve handle is
pushed fully closed.
C. Call your bulk oil provider.
D. Call you ASA for assistance.
EXPLANATION
A product cook is started on the right side of a
split vat or in a full vat that has a different
setpoint other than the current vat temperature.
A product cook is started on the right side of a
split vat or in a full vat that has a different
setpoint other than the current vat temperature.
TEMP Probe reading out of range
High limit reading is out of range.
High limit temperature is past more than 410°F
(210°C), or in CE countries, 395°F (202°C)
A component has failed in the high limit circuit
such as computer, interface board, contactor or
open-high limit.
Internal MIB software error
MIB detects ATO board connection lost; ATO
board failure
Dirty pad and it needs changed or it was
bypassed; filter pump problem
Drain valve was trying to open and confirmation
is missing
Drain valve was trying to close and confirmation
7-5
NOW?
YES/NO,

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: