Frymaster BK1814 Series Installation & Operation Manual page 22

Gas fryers
Table of Contents

Advertisement

1. Between G20- and G25-type Natural Gas, adjust the gas pressure at the regulator. (Refer to the
CE Standard Burner Manifold Gas Pressure Chart.) Do not change the orifice.
nd
2. Between a 2
family (G20 or G25) and a 3
a. Change the orifices.
b. Adjust the manifold pressure.
3. Affix the new label included with the conversion kit next to the existing rating plate stating that
the gas type has been converted. Remove any references to the previously used gas from the
existing rating plate.
Conversions can only be executed by qualified, factory-authorized personnel.
Pilot pressure adjustment
(remove cover screw to
access)
Pilot gas supply
connection.
Typical non-CE gas valve for electronic-ignition equipped fryers.
Frymaster BK1814 Series Gas Fryers
Chapter 3: Installation
CE GAS CONVERSION INSTRUCTIONS
rd
family gas (G30 Butane or G31 Propane):
3-8
Pressure flow adjustment
(remove cover screw to
access)
Regulator Vent
ON/OFF
Gas-Cock Knob