Machine Location; Input And Output Services - Raytheon SC125VNV Installation & Maintenance

Washer-extractor cabinet hardmount variable-speed
Table of Contents

Advertisement

Available languages

Available languages

Safety
Safe Operating Environment
(Continued)

Machine Location

. The concrete floor must be of
Foundation
sufficient strength and thickness to handle
the floor loads generated by the high
extract speeds of the machine.
Service/Maintenance Space .
sufficient space to allow comfortable
performance of service procedures and
routine preventive maintenance.
This is especially important in connection
with machines equipped with an AC
inverter drive.
Consult installation instructions for specific
details.
CAUTION
Replace all panels that are removed to
perform service and maintenance
procedures. Do not operate the machine
with missing guards or with broken or
missing parts. Do not bypass any
safety devices.

Input and Output Services

Water Pressure
. Best performance will be
realized if water is provided at a pressure
of 30–85 psi (2.0–5.7 bar). Although the
machine will function properly at lower
pressure, increased fill times will occur.
Water pressure higher than 100 psi
(6.7 bar) may result in damage to machine
plumbing. Component failure(s) and
personal injury could result.
Provide
SW019
1–6
Steam Heat (Optional) Pressure .
performance will be realized if steam is
provided at a pressure of 30–80 psi
(2.0–5.4 bar). Steam pressure higher
than 125 psi (8.5 bar) may result in
damage to steam components and may
cause personal injury.
For machines equipped with optional
steam heat, install piping in accordance
with approved commercial steam
practices. Failure to install the supplied
steam filter may void the warranty.
. For machines requiring
Compressed Air
compressed air service, best performance
will be realized if air is provided at a
pressure of 80–100 psi (5.4–6.7 bar).
Drainage System .
troughs large enough to accommodate
the total number of gallons that could
be dumped if all machines on the site
drained at the same time from the highest
attainable level. If troughs are used,
they should be covered to support light
foot traffic.
. For personal safety and for proper
Power
operation, the machine must be grounded
in accordance with state and local codes.
The ground connection must be to a
proven earth ground, not to conduit or
water pipes. Do not use fuses in place of
the circuit breaker. An easy-access cutoff
switch should also be provided.
Best
Provide drain lines or
F232097R1

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Uc125vnv

Table of Contents