Maintenance
Daily
(Continued)

End of Day

1. Clean the AC drive module filters:
a. Snap off the external plastic covers
which contain the filters.
b. Remove the foam filters from the
covers.
c. Wash the filters with warm water
and allow to air dry. Filters can be
vacuumed clean.
2. Clean the door gasket of residual detergent
and all foreign matter.
3. Clean washer's top, front, and side
panels with mild detergent. Rinse with
clean water.
4. Leave loading door open at the
end of each day to allow moisture
to evaporate.
Note: Unload the washer-extractor promptly
after each completed cycle to prevent moisture
buildup. Leave loading door open at the end of
each completed cycle to allow moisture to
evaporate.

Weekly

1. Check the washer-extractor for leaks.
a. Start an unloaded cycle to fill the
washer-extractor.
b. Verify that door and door gasket do
not leak.
c. Verify that the drain valve is
operating and that the drain system
is free from obstruction. If water does
not leak out during the wash segment,
drain valve is closed and functioning
properly.

Monthly

Note: Disconnect power to the washer-
extractor at its source before performing the
monthly maintenance procedures.
1. Each month OR after every 200 hours of
operation, lubricate bearings. (Locate the
bearing lubrication decal on the valve
panel, to the left of the vacuum breaker.)
The grease must have the following
characteristics:
• NLGI Grade 2
• Lithium-based
• Water-insoluble
• Anti-rusting
• Anti-oxidizing
• Mechanically stable