G. Capacitance Measurement (See figure 11)
Warning
To avoid damage to the Meter or to the equipment
under test, disconnect circuit power and discharge
all high-voltage capacitors before measuring
capacitance. Use the DC Voltage function to confirm
that the capacitor is discharged.
To avoid harms to you, please do not attempt to input
voltages higher than 60V DC or 30V AC.
To measure capacitance, connect the Meter as follows:
1.
Insert the red test lead into the
and the black test lead into the COM terminal.
2.
Press
button to select capacitance measurement
mode. Auto ranging is default.
3.
Connect the test lead across with the object being
measured. For the capacitor lead is less than 0.6mm,
It is recommended to use the multi-purpose socket
to proceed the measurement as the above figure 11.
It is more suitable for testing small capacitor, it can
reduce the influence of distributed capacitor,
terminal
COM
(figure 11)
31