D. Measuring Resistance
Warning
To avoid damages to the Meter or to the devices under
test, disconnect circuit power and discharge all the
high-voltage capacitors before measuring resistance.
To avoid harms to you, please do not attempt to input
voltages higher than 60V DC or 30V AC.
Two wire configuration measure resistance, connect
the Meter as follows: (see figure 7)
1.
Insert the red test lead into the V/
black test lead into the COM terminal at the front
panel.
2.
Press the
button to enter resistance measurement
mode. Auto ranging is default, the Meter will select
the appropriate range, and an annunciator on the
display will indicate measurement units. Or you
could select the manual ranging mode according to
the "Selecting a Measurement Range ( , AUTO
and
Button)" section.
24
terminal and the
Model UT805: OPERATING MANUAL
(figure 7)