Baby Lock Crown Jevel BLCJ18 Instruction And Reference Manual page 28

Hide thumbs Also See for Crown Jevel BLCJ18:
Table of Contents

Advertisement

Sound
V o l u m e
Mute
Overspeed Alarm
Back
Figure 32
Diagnostics
Motor
Needle
X Motion
Back
Figure 33
Diagnostics
Motor Sensor Test
Rotate the hand wheel SLOWLY.
Passing Test:
Regular pulsing beeps as you
rotate the hand wheel.
Failing Test:
A solid tone or no beeping at all
as you rotate the hand wheel.
Back
Figure 34
50%
Max
On
Off
Main
Speed
Keys
Y Motion
Main
Main
Sound Screen
Th e "Volume" portion of this screen has two buttons
and a sliding control. Pressing on the "Mute" button
turns the alarm volume off . Pressing the "Max" button
turns the volume to its loudest level. Pressing the slid-
ing control in any position sets the volume to the level
indicated in that control. Pressing and moving back
and forth across the sliding control will change the
volume up as it is moved left to right and down as it is
moved from right . Th e Over-Speed Alarm box allows
the user to turn the alarm on and off . (Figure 32)
Press the "Main" button to return to the "Regulated" or
"Manual" menu screen or the "Back" button to return
to the "More" menu screen.
Diagnostics Screen
Six diff erent diagnostics tests can be performed on the
machine. Th ese functions test the motion encoders,
the motor control functions, the key switches and the
internal position sensors. (Figure 33)
Press the "Main" button to return to the "Regulated" or
"Manual" menu screen or the "Back" button to return
to the "More" menu screen.
Diagnostics Tests
Motor Sensor Test
Th e "Motor" Sensor test can help you determine
whether there may be a problem with the Baby Lock
Crown Jewel motor. Slowly rotating the handwheel
should result in a pulsing audible "beep. " If you get a
constant solid "beep" or no "beep" at all, this indicates
a failed test and the machine should be inspected by a
qualifi ed Baby Lock repair technician. (Figure 34)
Press the "Main" button to return to the "Regulated" or
"Manual" menu screen or the "Back" button to return
to the "More" menu screen.
Needle Sensor Test
Th e Needle Sensor test will indicate whether the needle
position sensor is functioning properly. Rotating the
handwheel should result in a "beep" for half of a stitch
cycle followed by no "beep" for the other half. (Figure
35 on next page.)