Enter show temp to view the temperature of the G250/G350 CPU. This command also
displays the high and low temperatures that will trigger a temperature warning.
Use the show timeout command to display the amount of time in minutes the terminal
remains idle before timing out.
Enter show voltages to view the power supply voltages of the G250/G350.
Use the show utilization command to display information about CPU and memory
usage on the G250/G350.
Note:
Before using this command, you must first use the set utilization cpu
Note:
command to enable CPU utilization measurements.
Enter test led to test the system ALM, MDM and CPU LEDs on the front panel of the
G250/G350. The CPU and media module LEDs blink for five seconds.

Summary of device status commands

For more information about these commands, see Avaya G250 and Avaya G350 CLI
Reference, 03-300437.
Table 21: Device status commands
Command
set utilization
cpu
show faults
show image
version
show mg
list_config
show mgc
show mm
show module
show restart-log
Description
Enable CPU utilization measurements
Display information about currently active faults
Display the software version of the image on both memory banks of
the device
Display the current hardware and firmware configurations for the
installed media gateway equipment
Display information about the Media Gateway Controller with which
the G250/G350 is registered
Display information about media modules that are installed on the
G250/G350
Display brief information about the media modules installed in the
G250/G350
Display information about the last time the G250/G350 was reset
Viewing the status of the device
Issue 5 June 2008