Setting the time program for DHW heating
Stop optimisation
The stop optimisation ensures that the
DHW cylinder is always fully heated at
the end of the time phase with the oper-
ating status "Normal".
Note
This function is only active if a time pro-
gram has been set.
Extended menu:
1.
2. "DHW"
3. "Stop optimisation"
DHW heating outside the time pro-
gram
You can start DHW heating immediately
either with the "DHW heating once
only" or with the "Comfort function"
("party mode") independent of the time
program.
DHW heating once only
DHW is heated once to the "Set temper-
ature 2" (see page 27).
Setting the time program for DHW circulation pump
Further information about the DHW cir-
culation pump can be found under "Ter-
minology" on page 56.
(cont.)
Standard menu
1. "DHW"
2. "1 x DHW heating"
Note
Heating DHW once only terminates
automatically when the "Set temperature
2" has been reached.
DHW heating with the comfort func-
tion ("party mode")
The DHW cylinder will be heated to the
standard DHW temperature (see
page 24) if comfort function ("party
mode") has been started.
Standard menu
1. "Heating" or "Heating/cooling"
2. Where appropriate, select the heat-
ing/cooling circuit.
3. "Party mode"
■ The time program for the DHW circu-
lation pump is made up of time pha-
ses. Set an operating status for each
time phase ("5/25 cyc.", "5/10 cyc.",
"ON", see page 33).
DHW heating
31