Unit Installation

Installing Dial Backup and Network Interface Modules

The DIM plugs on to the NIM. The NIM is then installed into the rear panel option module slot. The
following tables list the installation steps. Also see Figure 24 on page 46 and Figure 25 on page 47.
For NetVanta modules with outside plant connections, ensure that all cables are
removed from the module before installing or removing it from the NetVanta chassis.
Always remove power from the unit prior to removing or installing a module.
Improper installation may result in damage to the modules.
Step
1
Remove power from the unit.
2
If the NIM is already in the NetVanta chassis, remove all cables, release the pins at both edges
of the NIM front panel and slide the module out of the chassis.
3
Carefully align the P1 connector on the NIM with the J1 connector on the DIM. Using only fingertip
pressure so that neither circuit board bends or flexes, ensure that the connectors are firmly seated.
Secure the DIM to the NIM using the screws and standoff posts supplied. See Figure 24.
4
Slide the NIM with the DIM attached into the NetVanta chassis, continuing with the normal NIM
installation (refer to Instructions for Installing the NIMs on page 47).
46
NetVanta 1000/1000R Series Hardware Installation Guide
Instructions for Installing the DIMs
Action

Figure 24. Installing DIMs

Copyright © 2006 ADTRAN, Inc.
61200500L1-34J