Installer System Test - Honeywell VisionPRO TH8000 Series Installation Manual

Visionpro th8000 series touch-screen programmable thermostat
Hide thumbs Also See for VisionPRO TH8000 Series:
Table of Contents

Advertisement

Installation Guide
Installer setup
Setup functions
0530
Adaptive Intelligent
Recovery™
0540
Program periods
0580
Compressor
protection
0600
Heat temperature
range stop
0610
Cool temperature
range stop
0640
Clock format
0650
Extended fan
timer (heat)
0660
Extended fan
timer (cool)
0670
Keypad lock
0680
Heat temperature
control
0690
Cool temperature
control
0700
Temperature
display offset
0701
Humidity display offset
0710
RESET

Installer system test

During installer setup, press
repeatedly until "Test" appears.
0120
DONE
Press DONE to terminate testing.
69-2389—03
Settings & Options
1
On
** See page 11
0
Off
4
4 program periods (Wake, Leave, Return, Sleep)
2
2 program periods (Wake, Sleep)
5
5 minute compressor off time
[Other options: 0, 1, 2, 3 or 4-minute off time]
90 Max. heat temperature setting is 90°F (32°C)
[Other options: 40-89°F (4°C to 32°C)]
50 Min. cool temperature setting is 50°F (10°C)
[Other options: 51-99°F (11°C to 37°C)]
12 12-hour time (i.e., "3:30 pm")
24 24-hour time (i.e., "15:30")
0
Off
[Other options: Fan runs for 30, 60, 90, or 120 seconds after
call for heat ends]
0
Off
[Other options: Fan runs for 30, 60, 90, or 120 seconds after
call for cool ends]
0
Keypad unlocked (fully functional)
1
Partially locked (access to temperature settings only)
2
Fully locked
2
Standard temperature control (recommended)
1
Choose if room is warmer than set temperature
3
Choose if room does not reach set temperature
2
Standard temperature control (recommended)
1
Choose if room is cooler than set temperature
3
Choose if room does not reach set temperature
0
Thermostat displays actual room temperature
[Other options: -3, -2, -1, 1, 2, 3°F offset (-1.5°C to 1.5°C)
0
0%
[Other options: -12% to 12%]
0
No reset
1
Reset installer options & program schedule to factory de-
fault (only date and time settings are retained)
t
20
(factory default in bold)
** See page 11
Test
number
TEST
DONE
Press
st
select test
10
System
status
1
0
MCR29488
to
Press
to
st
change status