Honeywell VisionPRO TH8000 Series Installation Manual page 7

Visionpro th8000 series touch-screen programmable thermostat
Hide thumbs Also See for VisionPRO TH8000 Series:
Table of Contents

Advertisement

Installer setup
Setup functions
0120
Year
(first two digits)
0130
Year
(second two digits)
0140
Month
0150
Date
0160
Schedule format
0165
Restore energy saving
0170
System type
0173
Heat Pump Type
0180
Fan control
(heating)
0190
Changeover valve
(O/B terminal)
0200
Auxiliary heat
0210
External fossil
fuel kit
0220
1st stage com-
pressor cycle rate
0230
2nd stage com-
pressor cycle rate
0240
1st stage heat
cycle rate (CPH=
cycles per hour)
0250
2nd stage heat cycle
rate (CPH)
0260
3rd stage heat
cycle rate (CPH)
Settings & Options
20 (2000-2099)
21 (2101-2178)
10 (2010)
[Other options: 00-99]
6
[Other options: 1-12]
15 [Other options: 1-31]
4
7-day programming
0
Non-programmable
0
No
1
Yes
1
1 heat/1 cool conventional
2
1 heat/1 cool heat pump (no aux. heat)
3
Heat only (2-wire systems)
4
Heat only with fan
5
Hot water Series 20 system (power to open & close zone
valves/normally open zone valves)
6
Cool only
7
2 heat/1 cool heat pump (with aux. heat)
8
2 heat/2 cool multistage conventional
9
2 heat/1 cool multistage conventional
10 1 heat/2 cool multistage conventional
11 2 heat/2 cool heat pump (no aux. heat)
12 3 heat/2 cool heat pump (with aux. heat)
0
Air to Air heat pump
1
Geothermal heat pump
0
Gas/Oil heat (equipment controls heating fan)
1
Electric furnace (thermostat controls heating fan)
0
O/B terminal controls valve in cooling
1
O/B terminal controls valve in heating
0
Electric backup heat
1
Fossil fuel backup heat
1
External fossil fuel kit controls backup heat
0
Thermostat controls backup heat (outdoor sensor required)
3
Recommended for most compressors
[Other options: 1, 2, 4, 5 or 6 CPH]
3
Recommended for most compressors
[Other options: 1, 2, 4, 5 or 6 CPH]
5
Gas or oil furnaces of less than 90% efficiency
1
Steam or gravity systems
3
Hot water systems & furnaces of 90%+ efficiency
9
Electric furnaces
[Other options: 2, 4, 6, 7, 8, 10, 11, 12 CPH]
5
Gas or oil furnaces of less than 90% efficiency
1
Steam or gravity systems
3
Hot water systems & furnaces of 90%+ efficiency
9
Electric furnaces
[Other options: 2, 4, 6, 7, 8, 10, 11, 12 CPH]
9
Electric auxiliary heat or electric furnaces
1
Steam or gravity systems
3
Hot water systems & furnaces of 90%+ efficiency
5
Gas or oil furnaces of less than 90% efficiency
[Other options: 2, 4, 6, 7, 8, 10, 11, 12 CPH]
7
VisionPRO
(factory default in bold)
TH8000 Series
TM
Continued on next page
69-2389—03