Installer setup
Setup functions
0390
Dehumidification Away
Mode
0391
Dehumidification Away
Mode Fan Setting
0392
Dehum. Away Mode
Low Limit Temperature
Setting
0393
Dehum. away mode
temp. setting
0394
Dehum. Away Mode
Dehum. Setting
0400
Ventilation control
0401
Number of
bedrooms
0402
Size of home
0403
Ventilation level
0404
Max. ventilation limit
0405
Ventilation fan action
0430
Ventilation lockout
0431
Ventilation high tem-
perature lockout
0432
Ventilation low tem-
perature lockout
0500
Furnace filter
change reminder
0502
Furnace filter
alert options
0510
Humidifier pad
change reminder
0520
UV lamp change
reminder
Settings & Options
0
No
1
Yes
0
Fan auto
1
Fan on
2
Fan circulate
76 Low limit temperature 76°F (24°C)
[Other options: 70°F to 80°F (21°C to 27°C)]
85 Low limit away temperature 85°F (29°C)
[Other options: 70°F to 99°F (21°C to 37°C)]
65 Away humidity level 65%
[Other options: 40% to 70%]
0
No ventilation
1
Vent on during all periods
2
Vent off during sleep period
3
Vent on during all periods with lockouts
4
Vent off during sleep period with lockouts
2
Two bedrooms
[Other options: 1 to 6]
10 1,000 square feet}
[Other options: 11 to 50 (1,100 to 5,000 square feet)]
160 CFM (cubic feet per minute)
[Other options: (30 to 195 CFM)]
50 50% ventilation limit
[Other options: 30% to 60% or 100%]
P
Meets ASHRAE 62.2 standard
F
Does not meet ASHRAE 62.2 standard
1
Ventilation on forces fan on
2
Ventilation does not force fan on
0
Off
1
Lockout for high temperatures
2
Lockout for low temperatures
3
Lockout for high and low temperatures
100 100°F (38°C): Settings 5°F apart (3°C)
[Other options: (90°F to 110°F/32°C to 43.5°C)]
-10 -10°F (-23.5°C): Settings 5°F apart (3°C)
[Other options: (-20°F to 0°F/-29°C to -18°C)]
0
Off
1
10-day run time
2
30-day run time
3
60-day run time
4
90-day run time
5
120-day run time
6
180-day run time
7
270-day run time
0
Timer counts Heat & Cool run time
1
Timer counts Cool run time only
0
Off
1
90 calendar days
2
180 calendar days
3
365 calendar days
0
Off
1
1 year
2
2 years
9
VisionPRO
(factory default in bold)
** See page 11
** See page 11
** See page 11
8 365-day run time
9 30 calendar days
10
60 calendar days
11
90 calendar days
12
120 calendar days
13
180 calendar days
14
365 calendar days
TH8000 Series
TM
Continued on next page
69-2389—03