Installation Guide
Installer setup
Setup functions
0280
Backlight
0300
Manual/Auto
changeover
0310
Auto changeover
deadband
0320
Temperature
display
0330
Daylight savings
0340
Remote sensor
0345
Dual Fuel Heat Pump
Control
**
0346
Dual fuel heat pump
upstage to furnace
timer
**
0347
Droop temperature
0350
Heat pump
compressor lockout
0360
Heat pump
auxiliary lockout
0371
Indoor Air Quality de-
vice on U1/U1
0372
Humidification Control
0374
Hum fan action
0379
Dehumidification
Control
0380
Dehumidify with air
conditioner
0383
Over cooling limit
0384
Dehumidification fan
control
0386
Whole house dehumid-
ification lockout
69-2389—03
Settings & Options
0
Backlight on for approx. 8 seconds after keypress
1
Backlight always on low intensity, full bright after keypress
(requires 24VAC connection)
0
Manual changeover (Heat/Cool/Off)
1
Automatic changeover (Heat/Cool/Auto/Off)
3
Heat/cool temperature 3°F apart (1.5°C)
[Other options: 2-9 (2°F to 9°F/1°C to 5°C)]
0
Fahrenheit
1
Celsius
2
Auto-change to daylight saving time
0
Daylight saving time is turned off
0
No remote sensor
1
Outdoor sensor (display only)
2
Outdoor sensor for control (select lockouts and frost protec-
tion)
** See page 11
3
Indoor sensor
4
Discharge air sensor (Required for Desert humidity control)
** See page 11
1
Droop Control
0
No droop control
2
Droop control with aux heat lockout
1
1 hour
0
Off
[Other options: 0.5, 1.5, 2-6, 8, 10, 12, 14, 16 hours]
2
2°F (1°C)
[Other options: 2-5 (2°F to 5°F/1°C to 2.5°C)]
0
No heat pump compressor lockout
[Other options: 5–60°F (-15°C to 15.5°C)]
0
No heat pump auxiliary lockout
[Other options: 5–65°F (-15°C to 18.5°C)]
0
None
1
Humidification
2
Dehumidification
3
Ventilation
0
Off
1
Humidify with no frost protection
3
Humidify with frost protection
8
Desert humidity control in heat, off, or cool; DATS required
0
Humidify only while fan is on
1
Humidifier forces fan on
2
Humidify only when heat it on
3
Humidifier operates independent of fan
0
None
1
Air conditioning with low speed fan
3
Whole house dehumidification
0
No dehumidification control
1
Thermostat controls dehumidification with air conditioner
high speed fan
** See page 11
3
3°F (1.5°C)
[Other options: 1-2 (1°F to 2°F/.5°C to 1°C)]
0
Fan turns on with dehumidifier
1
Dehumidifier operates independent of fan
0
Off
1
On
8
(factory default in bold)
** See page 11
** See page 11
** See page 11
** See pages 11–12
Continued on next page