Programmable Zero Offset - External Zero Offset - Siemens Sinumerik 810T User Manual

Basic version 3, software version 3
Table of Contents

Advertisement

3 Operating Sequences
3.1.5 Zero offset
3.1.5.2 Programmable zero offset
- external zero offset
a) Programmable zero offsets
The values for the G58 and G59 offsets can be written in the program.
You will find information on the programming of these zero offsets in Part 2,
"Programming", Section 2.5.
The programmed zero offset for the current part program % ... can be displayed.
Sequence of operation
Precondition:
You have selected the "AUTOMATIC" operating mode, with the operating mode selector
switch, symbol
and have called a program % ...
SETTING
DATA
Now operate the "SETTING DATA" softkey ...
PROG.
ZO
... and then the "PROGRAMMABLE ZERO OFFSET" softkey.
((Bild 810T/19 einmontieren))
3-20
This display appears.
You can now read the values for
"G58" and "G59" for the axes X and Z
axes (Q1,Q2,.., if present), but you
cannot change them.
© Siemens AG 1990 All Rights Reserved
09.91
6ZB5 410-0EP02
SINUMERIK 810T, GA3 (BN)

Hide quick links: