SECO-LARM E-941SA-600 Manual page 5

Electromagnetic lock 600-lb. (272kg), 1200-lb. (545kg) with led, bond sensor, weatherproof
Hide thumbs Also See for E-941SA-600:
Table of Contents

Advertisement

6.
Depending on the type of door being protected, drill holes according to the diagrams below:
Hollow Metal Door
5/8" (16mm)
Drill a 5/16" (8mm) dia. hole through the
armature-plate side of the door for the
armature screw. Then drill a 5/8" (16mm)
dia. hole for sexnut screw on the
opposite side of the door.
7.
Put a rubber washer between the two metal washers,
and place them over the armature screw between
the armature plate and the door. This allows the
plate to pivot around the screw to compensate for
door misalignment.
9
. Screw the two short self-tapping screws through the mounting plate's slotted holes, but do not over-tighten them.
Keeping them loose will allow for adjustment of the plate left or right so that the mounting plate and the armature
plate form a 90-degree angle. See the diagram below.
300-lb and 600-lb
mounting plate
SECO-LARM U.S.A., Inc.
5/16" (8mm)
1/4" (6.8mm) for M8x1.25 thread
The rubber washer will be
sandwiched between the
two metal washers.
Metal
washers
SECO-LARM
Reinforced Door
Drill a 1/4" (6.8mm)
dia. and 1" (25mm)
deep hole, tap for
M8x1.25 thread.
8.
Tighten the armature screw enough so that the
armature plate can withstand a break-in attempt, but
loose enough so that the armature plate can pivot
slightly. Make sure the anti-spin guide pins are in the
two guide pin holes.
Tip:
300-lb mounting plate
ELECTROMAGNETIC LOCK
Solid Core Door
1/2" (12 .7mm)
Drill an 5/16" (8mm) dia. hole on the
door for the armature screw, and drill a
1/2" (12.7mm) dia. and 1" (25mm) deep
hole for the sexnut screw.
Guide pins
Use a thread-locking compound
on the armature screw to ensure
a long-lasting installation.
90
Armature Plate
5/16" (8mm)
Armature
screw
Mounting Plate
5