Scytek electronic 2000RS Product Manual page 38

Vehicle security system with remote start
Table of Contents

Advertisement

6. Door Unlock Pulse. Selects between one pulse or two pulse operation for the door unlock output.
Many new import vehicles' factory door locking systems require two pulses on the proper wire to unlock
the doors. These systems can be interfaced directly without the use of relays or any additional circuitry
by programming the system for double unlock pulse.
7. Door Lock Pulse Length. Selects between a 1, 3 or 0.1 seconds output for door locking and
unlocking. Program to 3 seconds for vehicles equipped with vacuum door locking systems.
8. Passive Door Locking. Selects whether or not the system will automatically lock the doors during
Passive Arming and Auto Rearming mode.
9. Remote Start Confirmation Chirps. When enabled, system chirps before starter activated. When
disabled, no chirps will sound upon start.
Enable Auxiliary Start Activation. Enable to use the axillary start feature.
10. Ignore Open Door Report. Bypasses the open zone warning chirps for vehicles equipped with a
residual dome light circuit that remains on for a period of time after closing the door.
11. Auxiliary 1 Mode. Selects from momentary, 10 second timed, or latched operation for Auxiliary 1.
Momentary operation provides an output for as long as the transmitter button is pressed.(1-way
remote only)
Timed operation provides an output that turns on for 10 seconds each time the transmitter button is
pressed. If the button is pressed again during the 30 seconds, the output will turn off.
Latched operation provides an output that turns on when the transmitter button is pressed and
remains on until the transmitter button is pressed again.
Note: With the optional ScyNet network interface and Wizard software, any auxiliary function can be
programmed to output for 1 second up to 255 seconds.
12. Auxiliary 2 Mode. Selects from momentary, 10 second timed, or latched operation for Auxiliary 2.
Momentary operation provides an output for as long as the transmitter button is pressed.(1-way
remote only)
Timed operation provides an output that turns on for 10 seconds each time the transmitter button is
pressed. If the button is pressed again during the 30 seconds, the output will turn off.
Latched operation provides an output that turns on when the transmitter button is pressed and
remains on until the transmitter button is pressed again.
Note: With the optional ScyNet network interface and Wizard software, any auxiliary function can be
programmed to output for 1 second up to 255 seconds.
13. Auxiliary 3 Mode. Selects from momentary, 10 second timed, or latched operation for Auxiliary 3.
Momentary operation provides an output for as long as the transmitter button is pressed.(1-way
remote only)
Timed operation provides an output that turns on for 10 seconds each time the transmitter button is
pressed. If the button is pressed again during the 30 seconds, the output will turn off.
Latched operation provides an output that turns on when the transmitter button is pressed and
remains on until the transmitter button is pressed again.
Note: With the optional ScyNet network interface and Wizard software, any auxiliary function can be
programmed to output for 1 second up to 255 seconds.
14. Disarm with Auxiliary 1. When selected, activating the Auxiliary 1 output (usually used to open
the trunk) will disarm the alarm the system.
15. Aux 2 Auto Activate with Arm. When selected, the Auxiliary 2 output will activate when the
system is armed. This feature can be used to roll-up windows, close sunroofs, activate accessories,
etc. (will not activate if Aux 2 is set to "latched")
Page 34 -Galaxy 5000/2000RS-DBP

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

5000rsGalaxy 2000rs-dbp seriesGalaxy 5000rs-dbp series

Table of Contents