6. LOAD STATUS DISPLAY
1) Press power freezing / regular conditing and power refrigerating / power saving key for five seconds then
press temperature control key in the refrigerator after temperature display lamps on and off three times
2) This mode shows which lamps is being sourced signal from MICOM currently. This doesn' t mean the load is
operate due to the open wire or relay missing though the display shows the compressor operating.
3) Load status display return to normal mode after sixty seconds.
4) Follows are load status and related dispay.
NO
ITEM
FREEZER SUBORDINATE
1
COMP
2
F-FAN
3
FREEZER DEFROST HEATER
REFRIGERATOR SUBORDINATE
R-FAN, S-FAN
4
5
REFRIGERATOR DEFROST HEATER
MODE DISPLAY
6
INITIAL MODE
7
OVERLOAD
8
LOW TEMP MODE
DISPLAY LED
FREEZER " LOW"
RELEVANT LED ON DURING COMPRESSOR OPERATION
FREEZER " LOW,MID"
RELEVANT LED ON DURING F-FAN OPERATION
FREEZER " MID"
RELEVANT LED ON DURING FREEZER DEFROST HEATER ON.
REFRIGERATOR " LOW"
RELEVANT LED ON DURING S-FAN AND F-FAN OPERATION
REFRIGERATOR " MID"
RELEVANT LED ON DURING REFRIGERATOR DEFROST
POWER FREEZER
RELEVANT LED ON QITH INITIAL POWER INPUT.
POWER REFRGERATOR
RELEVANT LED ON QHEN ROOM-TEMP. IS OVER 35℃
POWER SAVING
RELEVANT LED ON QHEN ROOM-TEMP. IS BELOW 15℃
(LOAD STATUS DISPIAY TABLE)
-16-
DISPLAY