④ In case of the panel PCB Key selection is impossible.

4. In case of FAN do not run

REFRENCES
"Be sure to check cooling FAN under forced operation"
1. F-FAN, R-FAN and COMP COOLING are off when COMP is off.
2. Though the comp is on, the R-FAN is not always on because the FAN is off when the tem
perature was reached to the set point.
3. There is delaying time to run the fan after door open (COMP ON state). thedelay time varys
from ten seconds to one minute, (Forced operation included)
4. When closed MOTOR, it is stop state (After stopped, it is ON/OFF at ten minutes)
START
Is the connection of
cover O.K?
Y
Is MAIN-PCB commection
(CON50)O.K?
Y
Is PANEL-PCB connection O.K?
Y
Are there any keys already
predded?
N
Change PANEL-PCB
N
Re-connection connection failure
N
Re- connection
N
Re-connection connectionfailure
Y
Re-assemble PANEL COVER