Technical Specifications; Power Supply Specifications; Critical Alarm Relay Specifications; Copper Ethernet Port Specifications - RuggedCom RX1512 Installation Manual

Rugged layer 3 switch and router
Hide thumbs Also See for RX1512:
Table of Contents

Advertisement

RUGGEDCOM RX1512
Installation Guide

Technical Specifications

Section 4.1

Power Supply Specifications

Table: Power Supply Specifications
Power
Supply Type
Internal
a
Power consumption varies based on configuration.
Section 4.2

Critical Alarm Relay Specifications

Table: Form C Contact Relay Specifications
Section 4.3

Copper Ethernet Port Specifications

The RX1512 can be ordered with several different modules which contain 10/100Tx or 10/100/1000Tx Ethernet
ports. All copper Ethernet ports have the following specifications:
Table: Copper Ethernet Port Specifications
Parameter
Speed
Duplex
Cable-Type
Wiring Standard
Max Distance
Connector
Isolation
Power Supply Specifications
Input Range
Min
Max
10 VDC
72 VDC
Voltage
30VDC
Internal
Max. Power
Fuse Rating
Consumption
6.3A
27W Max (TBD)
Specification
10/100 or 10/100/1000 Mbps
FDX / HDX
> Category 5
TIA/EIA T568A/B
100 m
RJ45
M12 8-Pin A-Coded
M12 4-Pin D-Coded
1.5kV
Technical Specifications
Max Power
Connections
a
Output
Pluggable
20W (TBD)
terminal block
Current
2A
Notes
Auto-negotiating
Auto-negotiating
Shielded/Unshielded
Auto-Crossover, Auto-Polarity
RMS 1-minute
Chapter 4
31

Advertisement