Correcting The Note Timing (Quantize); Erasing Unwanted Data (Erase) - Roland Workstation GW-8 Supplementary Manual

Workstation
Hide thumbs Also See for Workstation GW-8:
Table of Contents

Advertisement

Correcting the Note Timing (Quantize)

This function corrects the timing of the performance data in the
specified region.
1. In the "Style Edit Menu," select "1. Quantize" and press
[ENTER].
The STYLE EDIT QUANTIZE screen will appear.
2. Use [
] [
] [
] [
parameter you want to change, and use the VALUE dial to
make the desired setting.
Parameter
Value
ADrum, ABass,
PART
Acc1–6, ALL
CHORD
Maj, min, 7th
INT1–4,
MAIN1–4,
DIVISION
FILL1–4,
END1–4
From
0001: 01:
(MEAS:
000–
BEAT: TICK)
0001: 01:
To (MEAS:
BEAT: TICK)
000–
1/4, 1/8, 1/
8T, 1/16, 1/
Resolution
16T,
1/32, 1/32T,
1/64
Strength
0–100%
] to move the cursor to the
Explanation
Selects the Style part to
which the Quantize
operation is to be applied.
Selects the chord.
Selects the division.
Specifies the beginning of
the region to which
Quantize is to be applied.
Specifies the end of the
region to which Quantize
is to be applied.
Specifies the timing
interval for quantization.
Select the shortest note
value used in the region to
be quantized.
Specifies the amount of
timing correction applied
relative to the Resolution
timing interval.
If you select "100%,"
notes will be corrected all
the way to precise
intervals of the specified
Resolution.
With lower values, the
correction will not be as
tight, and with a setting of
0% there will be no
correction at all.
Parameter
Value
C– (Note
Note
Range Max
Range Min
value)
(Note Range
Note
Range Max
Min value)–G9
3. Select "EXECUTE" and then press [ENTER].
It is not possible to restore the data to its original state after
executing this operation.

Erasing Unwanted Data (Erase)

This function erases performance data from the specified
region. The erased data will be converted to rests; the
measures themselves will remain.
1. In the "Style Edit Menu," select "2. Erase" and press
[ENTER].
The STYLE EDIT ERASE screen will appear.
2. Use [
] [
] [
] [
parameter you want to change, and use the VALUE dial to
make the desired setting.
Parameter
Value
ADrum, ABass,
PART
Acc1–6, ALL
CHORD
Maj, min, 7th
INT1–4,
MAIN1–4,
DIVISION
FILL1–4,
END1–4
From
(MEAS:
0001: 01: 000–
BEAT: TICK)
To (MEAS:
0001: 01: 000–
BEAT: TICK)
Creating a New Style
Explanation
Specifies the lowest pitch
to be quantized.
Specifies the highest pitch
to be quantized.
] to move the cursor to the
Explanation
Selects the Style part
from which data is to be
erased.
Selects the chord.
Selects the division.
Specifies the beginning
of the region from which
data is to be erased.
Specifies the end of the
region from which data
is to be erased.
13

Advertisement

Table of Contents
loading

Table of Contents