TCP Error Messages

3062: ZPWY-ERR-TCP-BADDBCSKKDATA1

Translation routines were unable to correctly translate data from internal format to the
external format required by the device.
This error does not appear in the RETCODE token or in an error list; it appears only in
response to a STATUS TCP or STATUS TERM command.
Effect. The program terminates abnormally.
Recovery. Abort the terminal from the Pathway subsystem and either upgrade the
terminal to support the application data or modify the requester-server application to
conform to the device environment.

3063: ZPWY-ERR-TCP-BADDBCSKKDATA2

Translation routines were unable to correctly translate data from internal format to the
external format required by the device.
This is the same error as reported by 3062, except that, for internal reasons, the data
descriptor number is not available for reporting in the message. The offset can be
mapped to the SCOBOLX verb that failed if the compiler ?MAP directive is used.
This error does not appear in the RETCODE token or in an error list; it appears only in
response to a STATUS TCP or STATUS TERM command.
Effect. The program terminates abnormally.
Recovery. Abort the terminal from the Pathway subsystem and either upgrade the
terminal to support the application data or modify the requester-server application to
conform to the device environment.

3064: ZPWY-ERR-TCP-DATATRUNCATION

The TCP displayed a truncated data item. Truncation can occur with double-byte
character data items that equal the maximum field length specified. A screen field
containing double-byte characters was truncated for one of the following reasons:
Insertion of Shift In-Shift Out characters into a data stream being sent to an IBM
device caused the number of displayable characters to exceed the field size.
A double-byte character started on the last column of a Fujitsu 3270 device. As a
result, a space was inserted into the data stream causing the number of
displayable characters to exceed the field size.
A double-byte character started on the last column of a JET6530 or PCT emulator.
As a result, a space was inserted into the data stream causing the number of
displayable characters to exceed the field size.
This error does not appear in the RETCODE token or in an error list; it appears only in
response to a STATUS TCP or STATUS TERM command.
Effect. None.
NonStop Pathway/iTS Management Programming Manual—426749-002
Error-Message Range 3000 Through 3999
12 -17