Troubleshooting - Quadra-Fire QVI-30FB Owner's Manual

Hide thumbs Also See for QVI-30FB:
Table of Contents

Advertisement

Troubleshooting

Symptom
4. Frequent pilot
a. Pilot flame may be too high or
outage problem.
too low, or blowing (high),
causing pilot safety to drop out.
5. The pilot and main
a. No LP in tank.
burner extinguish
b. Inner vent pipe leaking exhaust
while in operation.
gases back into the system.
c. Glass too loose and air tight
packet leaks in corners after
usage.
d. Bad thermopile or
thermocouple.
e. Improper vent cap installation.
6. Glass soots.
a. Flame impingement.
b. Improper venturi setting.
c. Debris around venturi.
7. Flame burns blue
a. Insufficient oxygen being
and lifts off burner.
supplied.
24
(continued)
Possible Cause
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Corrective Action
Clean and adjust the pilot flame for maximum flame impingement on
thermocouple. Follow lighting instructions carefully.
Check the LP (propane) tank. Refill the fuel tank.
Check for gas leaks.
Tighten the corner.
Replace if necessary.
Check for proper installation and freedom from debris or blockage.
Adjust the log set so that the flame does not excessively impinge on it.
Adjust the air shutter at the base of the burner.
Inspect the opening at the base of the burner. NO MATERIAL SHOULD
BE PLACED IN THIS OPENING.
Ensure that the vent cap is installed properly and free of debris. Ensure
that the vent system joints are tight and have no leaks.
Ensure that no debris has been placed at the base of, or in the area of
the air holes in the center of the base pan beneath the burner.
Ensure that the glass is tightened properly on the unit, particularly on top
corners.