Quadra-Fire QVI-35FB-S Owner's Manual

Installation and operation
Table of Contents

Advertisement

Quick Links

Model:
QVI-35FB-S
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions
and the manufactured home construction and safety standard,
Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240MH, in Canada.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
R
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
A CO detector shall be installed in the room where the appliance
in installed.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
1

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire QVI-35FB-S

  • Page 1 fi tter. A CO detector shall be installed in the room where the appliance in installed. Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 Owner’s Manual Installation and Operation • Leave this manual with party responsible for use and operation.
  • Page 2: Congratulations

    The information contained in this Owner’s Manual, unless noted otherwise, applies to all models and gas control systems. Your new Quadra-Fire gas fi replace will give you years of durable use and trouble-free enjoyment. Welcome to the Quadra-Fire family of fi replace products! We recommend that you record the following pertinent information about your fi...
  • Page 3: Table Of Contents

    D. Contact Information ......41 = Contains updated information. Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08...
  • Page 4: Limited Lifetime Warranty

    Page 1 of 2 Wood Pellet Electric Wood Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 Components Covered Venting All Parts and Material Except as covered by Conditions, Exclusion, and Limitations listed Igniters, Electronic Components,...
  • Page 5 If warranty service is needed, you should contact your installing dealer. If the installing dealer is unable to provide necessary parts or components, contact the nearest authorized HHT dealer or supplier. Page 2 of 2 Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 4021-645A 09-01-08...
  • Page 6: Listing And Code Approvals

    A 110-120 VAC circuit for this product must be protected with compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 Maximum Minimum Models...
  • Page 7: User Guide

    fi replace according to operating instructions could cause fi re or injury. DECORATIVE DOORS (NOT SHOWN) SECTION 2.D. FIXED GLASS ASSEMBLY (NOT SHOWN) SECTION 12.G. HEARTH CLEAR SPACE SECTION 2.C. Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 MANTEL...
  • Page 8: Clear Space

    • Ensure that the glass is sealed and in the proper position and that the integral barrier is in place. WARNING! Risk of Fire/Asphyxiation! DO NOT oper- ate fi replace with fi xed glass assembly removed. Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08...
  • Page 9: Standing Pilot Ignition

    Bedroom or a Bedsitting Room. For assistance or additional informa- tion, consult a qualifi ed installer, ser- vice agency or the gas supplier. Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 LIGHTING INSTRUCTIONS 1. Open control access panel. 2. Turn off all electric power to the appliance.
  • Page 10: After Appliance Is Lit

    Noise is caused by metal expanding and contracting as it heats up and cools down, similar to the sound produced by a furnace or heating duct. This noise does not affect the operation or longevity of the appliance. Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 SOLUTIONS...
  • Page 11: Maintenance And Service

    (building additions, decks, fences, or sheds). See Section 6. • Inspect for corrosion or separation. • Verify weather stripping, sealing and fl ashing remains intact. • Inspect draft shield to verify it is not damaged or missing. Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08...
  • Page 12: Maintenance Tasks-Service Technician

    fl ame pattern. Clean or replace orifi ce spud as necessary. • Inspect thermocouple/thermopile for soot, corrosion and deterioration. Clean with emery cloth or replace as required. • Verify thermocouple/thermopile millivolt output. Replace pilot as necessary. Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08...
  • Page 13 Figure 3.1 Standing Pilot Flame Patterns Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08...
  • Page 14: Installer Guide

    GAS LINE (SECTION 9) ACCESS THROUGH EXISTING MASONRY OR WOODBURNING FIREPLACE Figure 4.1 Typical System-Masonry Chimney Installer Guide VERTICAL TERMINATION CAP Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 (SECTION 8F ) MANTEL AND MANTEL LEG (SECTIONS 5 & 11) SURROUND...
  • Page 15 VENT PIPE (SECTION 8) GAS LINE (SECTION 9) ACCESS THROUGH EXISTING MASONRY OR WOODBURNING FIREPLACE Figure 4.2 Typical System-Vent Pipe Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 VERTICAL TERMINATION CAP (SECTION 8F ) MANTEL AND MANTEL LEG (SECTIONS 5 & 11)
  • Page 16: Design And Installation Considerations

    DO NOT use this appliance if any part has been under water. Call a qualifi ed technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water. Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08...
  • Page 17: Fireplace Size Requirements

    fl oor as tested for and as noted above. MINIMUM FIREPLACE SIZE Location In addition to these dimensions, also reference Mantel and Wall Projections (Section 5.B). Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 FRONT VIEW QVI-35FB-S Inches Millimeters 22-5/8 574.7...
  • Page 18: Mantel And Wall Projections

    Note: All measurements in inches. EXHAUST VENT PIPE Figure 5.2 Clearances to Mantels or other Combustibles Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 INLET AIR 12 in. MAX. VENT PIPE MANTEL 12 in. MIN. MEASUREMENTS FROM TOP EDGE OF UNIT...
  • Page 19: Termination Locations

    VERTICAL WALL ROOF PITCH IS X/ 12 Figure 6.2 Staggered Termination Caps H (Min.) Ft. Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 18 in. minimum 152 mm/508 mm 457 mm 20 in. and over 0 in. minimum Gas, Wood or Fuel Oil...
  • Page 20: Installation Preparation

    An outlet box may be installed in a bottom back corner of the fi replace to permit fans or other optional accessories to be used. Alternatively, the supplied power cord may be routed out onto the hearth to a nearby outlet. Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08...
  • Page 21: Installing Vent Pipe And Appliance

    WARNING: DO NOT BLOCK PIPE END WITH INSULATION OR ANY OTHER SEALING MATERIAL STAINLESS STEEL PIPE - 3 FT. MIN. REQUIRED (INCLUDED) INLET AIR VENT PIPE COLLAR ATTACHMENT BRACKET Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08...
  • Page 22: Placing, Securing And Leveling The Appliance

    fi replace as shown below or in the control cavity to the left of the valve. SLIDE PLATE SLIDE PLATE HANDLE HANDLE EXISTING BOTTOM OF Figure 8.4 Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 EXISTING SIDE REFRACTORY REMOTE RECEIVER UNIT FIREPLACE...
  • Page 23: Installing Adaptor And Termination Cap

    VENT PIPE WARNING: DO NOT BLOCK THIS PIPE END! INLET AIR VENT PIPE Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 Factory Built Wood Burning OPTIONAL LINK-ZC-ADPB FOR USE WITH CLASS A WOODBURNING PIPE Remove 18 inch x 18 inch fl ashing on cap by removing 3 screws.
  • Page 24: Gas Information

    • In the USA: Reduce burner orifi ce 4% for each 1000 feet above 2000 feet. • In the CANADA: Reduce burner orifi ce 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility. Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08...
  • Page 25: Electrical Information

    • If desired an additional wall switch or thermostat may be added to system as shown in Figure 10.2). ON/OFF SWITCH Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 REMOTE SWITCH PIGTAIL OPTIONAL WALL SWITCH, THERMOSTAT OR REMOTE...
  • Page 26: Junction Box Installation

    • Reinstall the cover plate back on the unit. Make sure the fan does not make contact with the back wall to prevent noise from vibration. Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 COVER PLATE GROUND...
  • Page 27 C RATED WIRE. Figure 10.5 Fan Wiring Diagram JUNCTION BOX GROUND 110-120 VAC BEND GROUND WIRE UP TABS (ATTACH TO ANY METAL SURFACE) Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 BLOWER RECEPTACLE BLOWER JUNCTION TEMPERATURE SENSOR SWITCH SPEED CONTROL (RHEOSTAT)
  • Page 28: Finishing

    Note: All measurements in inches. EXHAUST VENT PIPE Figure 11.1 Clearances to Mantels or other Combustibles Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 INLET AIR 12 in. MAX. VENT PIPE MANTEL 12 in. MIN. MEASUREMENTS FROM TOP EDGE OF UNIT...
  • Page 29: Appliance Setup

    The embers provided should be enough for 3 to 5 applications. EMBER MATERIAL (TOP SURFACE, AND FRONT) Figure 12.1 Placement of Embers Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 ® just in front BURNER PAN SHUTTER...
  • Page 30: Install The Log Assembly

    Log Set (FB-GRAND-S Shown) 4 LOCATING TABS (A-D) 1 LOCATING TINE (E) 2 3 4 Locating Tabs Place log #1 onto the grate. Push log back until it rests against locating Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 2178-910 8/08...
  • Page 31 Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 LOG NUMBER 2 (SRV768-704): onto grate such that tab C fi ts into the slot on the bottom surface of the log. The right side of the log rests between the front grate tine and locating tine E. The cutout on the log should contact the corresponding tine.
  • Page 32 Place log #4 across both fl at spots on log #1 and log #3, with the “Y” in log #4 placed on log #1. The back of log #4 should make contact with the back of the fi rebox. Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08...
  • Page 33: Fixed Glass Assembly

    Adjust air shut- ter for longer vertical runs. NOTICE: If sooting occurs, provide more air by opening the air shutter. Air Shutter Settings QVI-35FB-S FIREBOX Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 Full Open Full Open...
  • Page 34: Troubleshooting

    With the pilot in the ON position, disconnect the thermopile leads from the valve. Take a reading at the thermopile leads. The read- ing should be 350 millivolts minimum. Replace the thermopile if the reading is below the minimum. Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 Corrective Action...
  • Page 35 Ensure that the glass is tightened properly on the unit, particularly on top corners. Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 Corrective Action...
  • Page 36: Reference Materials

    Location Inches Millimeters 22-1/2 8-3/4 33-3/4 30-9/16 23-7/8 18-7/16 25-3/8 24-1/2 Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 4 in. 102 mm 13-3/4 in. 350 mm 1-1/16 in. 28 mm ELECTRICAL ACCESS (IF EQUIPPED) ø 2-13/16 in. 71 mm 3-9/16 in.
  • Page 37: Vent Kits Components

    FLEX3-30/2: Two 3 inch fl exible liners expands to 30 feet each. FLEX-CNCT: Connector kit - 3 inch liner to 3 inch liner, one connector per kit. Figure 15.3 Direct Vent Flex Liner Accessory Kits Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 FLASH-DAMP LINK-ZC-ADP SVRLINK-ADP FLEX3-30...
  • Page 38: Log Set Assembly

    QVI-35FB-S C. Service Parts Beginning Manufacturing Date: Dec. 2008 Service Parts Diagram Ending Manufacturing Date: ______ Log Set Assembly Part number list on following page. Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08...
  • Page 39: Service Parts List

    Conversion Kit LP Regulator NG Regulator LP Pilot Orifi ce NG Pilot Orifi ce LP Additional service part numbers on following page. COMMENTS Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 QVI-35FB-S Stocked at Depot PART NUMBER LOGS-CFXGB SRV768-701...
  • Page 40 Flex Ball Valve Assembly Valve NG Valve LP Flame Control Knob Pilot Control Knob Bracket: Valve COMMENTS Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 QVI-35FB-S Beginning Manufacturing Date: Dec. 2008 Ending Manufacturing Date: ______ Stocked at Depot PART NUMBER...
  • Page 41: Contact Information

    D. Contact Information Please contact your Quadra-Fire dealer with any questions or concerns. ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ • Important operating a n d m a i n t e n a n c e instructions included.