FEED PLUG
THROUGH HOLE
JUNCTION
BOX
SCREW
Figure 9.
PROVIDED
Junction box installation
Serving the blower
On units already installed removal of decorative front, sur-
round and gas insert is required.
• Detach flexible liner from the top of unit.
• Remove the four screws on the coverplate (see Figure 11).
• Bend up the tabs on the base pan (see Figure 10).
BLK
BLK
BLK
TEMPERATURE
SENSOR SWITCH
NOTE: IF ANY OF THE ORIGINAL WIRE AS SUP-
PLIED WITH THE APPLIANCE MUST BE RE-
PLACED, IT MUST BE REPLACED WITH TYPE
105
0
C RATED WIRE.
Figure 10. Fan Wiring Diagram
18
INSERT STRAIN RELIEF
AROUND CORD IN THIS END
FROM OUTSIDE OF UNIT
SIDEWALL
VARIABLE SPEED CONTROL
JUNCTION BOX
BLK
BLK
BLK
BLK
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
To service or clean:
• Remove the ground wire of the fan can clip on the side of
the base pan.
• Remove the blower in between the bend up tabs.
• Install and wire the blower per instruction shipped with
the fan.
• Reinstall the blower in reverse order. Make sure the fan
does not make contact with the back wall.
Figure 11.
REMOTE
RECEPTACLE
BLK
BLK
WHT
WHT
GROUND
GRN
WHT
110-120 VAC
FAN
BEND UP
TABS
COVER
FAN
PLATE
GROUND
WIRE
BLOWER RECEPTACLE
BLOWER
REMOTE
OUTLET
JUNCTION
BOX
OUTLET
TEMPERATURE
SENSOR SWITCH
SPEED CONTROL
(RHEOSTAT)
GROUND WIRE
(ATTACH TO ANY
METAL SURFACE)
FAN

Hide quick links: