Hot Plate - Model E24-12H; E18Fbl & E18Sfbl - Garland E22 series Installation Manual

E22 series; e24 series; e18 series; e20 series electric units
Table of Contents

Advertisement

INSTALLATION continued
Broilers Without Splatter
Guard
Sides
9" (229mm)
Back
9" (229mm)
Electrical Connections
For supply connection, use wire suitable for 75°C (167°F).
Electrical connection may be made though the knockout at
the rear of the unit to the terminal block located (E22-12B &
E22-24B) on the main bottom, left side, or (22-36B) on the
main bottom center. Access to the terminal box is gained by
removing the grease hopper (grasp upper front panel and
withdraw). Remove two 10-24 hex nuts securing the terminal
box cover, lift and remove.
Controls
Infinite switches are used to control the heating units:
Hi to 5
High heat
5 to 3
Medium heat
3 to Lo
Low heat
Setting of switches between the numbers will give
intermediate heat. Switches are reversible and may be
turned right or left.
Hot Plate – Model E24-12H
Serial Plate Location
The serial plate is located on the main back.
Wall Clearances
Do not install closer to a wall of combustible material than:
Sides
1" (25mm)
Back
1" (25mm)
Electrical Connections
For supply connection, use wire suitable for 75°C (167°F).
Electrical connection may be made though the knockout
at the rear of the unit to the terminal block located on the
inside left rear of the unit. Access to the terminal box is
gained by removing the back cover plate at the rear of the
unit.
Part # P66 (01/25/08)
Broilers With
Splatter Guard
Sides
3" (76mm)
Back
1" (25mm)
Controls
Infinite switches are used to control the heating units:
Hi to 5
High heat
5 to 3
Medium heat
3 to Lo
Low heat
Setting of the switches between the numbers will give
intermediate heat. Switches are reversible and may be
turned right or left.
Fryers – Model E24-31F, E24-31SF,
E24-31FBL, E24-31SFBL, E18F,
E18SF, E18FBL & E18SFBL
Serial Plate Location
For the E24 series, the serial plate is located on the back of
the control wiring compartment, to access remove fry bowl.
For the E18 series the serial plate is located on the top of the
control wiring compartment, to access remove the grease
drawer or fryer bowl.
Wall Clearances
Do not install closer to a wall of combustible material than:
E24 Series
Sides
0"
Back
0"
Electrical Connections
For supply connection use wire suitable for 60°C (140°F).
Electrical connection may be made though the knockout at
the rear or bottom of the unit to the terminal block, located
on the inside rear of the unit. Access to the terminal box is
gained by removing the fryer bowl. Remove the rear shield,
remove three 10-24 hex nuts securing the terminal box
cover, remove the terminal box cover.
E18 Series
Sides
1" (25mm)
Back
1" (25mm)
Page 9

Advertisement

Table of Contents
loading

Table of Contents