SPECIFICATIONS: HOT PLATES

STRAIGHT (STD) OR FLUSH-REAR
GAS INLET w/REGULATOR
1.7"
[43mm]
4.0"
[102mm]
*
32.0"
[814mm]
* Please add 5" (127mm) in overall depth
with attachment condiment rail option
4.0"
[102mm]
Model #
GTOG12-2
11-13/16 (300)
GTOG24-4
23-5/8 (600)
GTOG36-6
35-7/16 (900)
GTOG48-8
47-1/4 (1200)
SUPPLY OPERATING PRESSURE
NATURAL GAS
"WC
MBar
"WC
7
17.5
Page 4
Garland Commercial Ranges Ltd.
1177 Kamato Road,
Mississauga, Ontario
L4W 1X4 CANADA
7.6"
[192mm]
1.7"
[43mm]
WIDTH
Width
Height
In (mm)
(w/std legs)
13 (330)
MANIFOLD OPERATING PRESSURE
PROPANE
NATURAL GAS
Mbar
"WC
11
27.5
4.5
General Inquires 1-905-624-0260
USA Sales, Parts and Service 1-800-424-2411
Canadian Sales 1-888-442-7526
Canada or USA Parts/Service 1-800-427-6668
For use with Natural or Propane gas only.
Gas input ratings shown for installations up to
2000 ft., (610m), above sea level. Please specify
altitudes over 2000 ft. and gas type when ordering.
27.2"
Garland/U.S. Range products are not approved
[691mm]
or authorized for home or residential use, but are
intended for commercial applications only.
Garland/U.S. Range will not provide service,
warranty, maintenance or support of any kind
other than in commercial applications.
4.0"
[102mm]
.
15.8"
13.0"
[402mm]
[330mm]
Total Input (BTU)
Depth
In (mm)
NAT
60,000
120,000
32 (814)
180,000
240,000
PROPANE
MBar
"WC
Mbar
11
10
24.5
26.0"
[660mm]
Shipping Information
PRO
Lbs/Kg
52,000
73/33
104,000
135/61
156,000
191/87
208,000
247/112
CLEARANCES
INSTALLATION TO COMBUSTIBLE
Sides
Rear
7" (178mm)
6" (152mm)
Form# GTOG (11/03/11)
Part # 4528529 Rev. 1 (11/03/11)
5.3"
[136mm]
Cu Ft
4
8
25
33