Garland GIU2.5 Installation And Operation Manual

Induction single, dual and wok table top units
Hide thumbs Also See for GIU2.5:

Advertisement

GARLAND INDUCTION SINGLE, DUAL AND WOK
TABLE TOP UNITS, MODELS: GIU2.5, GIU3.5, GIU5.0,
GIU3.5 DUAL, GIU5.0 DUAL, GIWOK3.5 & GIWOK5.0

FOR YOUR SAFETY:

DO NOT STORE OR USE GASOLINE
OR OTHER FLAMMABLE VAPORS OR
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY,
OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent
using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed,
or which has been modified or repaired using unauthorized parts or by unauthorized service agents.
For a list of authorized service agents, please refer to the Garland web site at http://www.garland-group.com.
The information contained herein, (including design and parts specifications), may be superseded and is subject
to change without notice.
GARLAND COMMERCIAL INDUSTRIES
185 East South Street
Freeland, Pennsylvania 18224
Phone: (570) 636-1000
Fax: (570) 636-3903
Part # 4520896 (01/31/08)
Part # 4520896 (01/31/08)
INSTALLATION AND
OPERATION MANUAL
86037
APPLIANCE
WARNING:
GARLAND COMMERCIAL RANGES, LTD.
1177 Kamato Road, Mississauga, Ontario L4W 1X4
CANADA
Phone: 905-624-0260
Fax: 905-624-5669
C
CM
CONFORMS TO UL-197 & NSF-4 CERTIFIED TO
CAN/CSA C22.2NO. 109 VDE EN60335-2-38.
PLEASE READ ALL SECTIONS OF THIS MANUAL
AND RETAIN FOR FUTURE REFERENCE.
THIS PRODUCT HAS BEEN CERTIFIED AS
COMMERCIAL COOKING EQUIPMENT AND
MUST BE INSTALLED BY PROFESSIONAL
PERSONNEL AS SPECIFIED.
INSTALLATION AND ELECTRICAL CONNECTION
MUST COMPLY WITH CURRENT CODES:
IN CANADA - THE CANADIAN ELECTRICAL
CODE PART 1 AND / OR LOCAL CODES.
IN USA – THE NATIONAL ELECTRICAL CODE
ANSI / NFPA – CURRENT EDITION.
© 2004 Garland Commercial Industries, Inc.
Enodis UK LTD.
Swallowfield Way, Hayes, Middlesex UB3 1DQ ENGLAND
Telephone: 081-561-0433
Fax: 081-848-0041
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Garland GIU2.5

  • Page 1: For Your Safety

    Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation instructions provided with the product, or any product that has its serial number defaced, obliterated or removed, or which has been modified or repaired using unauthorized parts or by unauthorized service agents.
  • Page 2 Page 2 Part # 4520896 (01/31/08)
  • Page 3: Table Of Contents

    TABLE OF CONTENTS DIMENSIONS AND SPECIFICATIONS, GIU 2.5 ......4 DIMENSIONS AND SPECIFICATIONS, GIU 3.5/5.0 ..... . 5 DIMENSIONS AND SPECIFICATIONS, GIU 3.5/5.0 DUAL .
  • Page 4: Dimensions And Specifications, Giu 2.5

    DIMENSIONS AND SPECIFICATIONS, GIU 2.5 2-3/16"(55mm) 3-5/16"(84mm) 1-3/16"(30mm) 1-3/32"(28mm) 1-3/8"(35mm) 1-3/8"(35mm) 6'POWERCORD, (60HzMODELSONLY) 1-21/32"(42mm) 10-7/32" (260mm) 12-19/32" (320mm) PLUG CONFIGURATIONS: Electrical Model Plug Characteristics 208V/60Hz/1Ø GUI-2.5 240V/60Hz/1Ø Electrical Loading: Model Watts 208/60/1 208/60/3 240/60/1 230/50/1 400/50/3 440/60/3 GUI-2.5 2500 12 amp 9 amp 10 amp Page 4...
  • Page 5: Dimensions And Specifications, Giu 3.5/5.0

    DIMENSIONS AND SPECIFICATIONS, GIU 3.5/5.0 5-3/8" 3-3/8" (138mm) (97mm) removable washable 7-7/8" air lter freshair (198mm) "6'cordandplug 2-5/8"(65mm) (208/240volt,60cycleunitsonly)” 2-3/4"(70mm) 8-3/8"(210mm) viewA:exhaust 12-5/8"(320mm) 5-3/4" (144mm) exhaust 15"(380mm) PLUG CONFIGURATIONS: Electrical Model Plug Characteristics 208V/60Hz/1Ø GMUI-3.5 240V/60Hz/1Ø GMUI-5.0 208V/60Hz/3Ø Electrical Loading: Model Watts 208/60/1...
  • Page 6: Dimensions And Specifications, Giu 3.5/5.0 Dual

    DIMENSIONS AND SPECIFICATIONS, GIU 3.5/5.0 DUAL 2-5/8”(65mm) 6-3/8” 3-1/4”(80mm) (160mm) 2-1/4”(55mm) exhaust washable removable air lter 2”(50mm) 6'cordandplug freshair 6-7/8” (208/240 volt, 60cycleunitsonly) 7-3/8”(188mm) (172mm) 12-5/8” 22-7/8”(580mm) (320mm) 27-5/8”(700mm) Plug Configurations: Electrical Model Plug Characteristics GUI-3.5 DUAL 208V/60Hz/3Ø GUI-5.0 DUAL 208V/60Hz/3Ø...
  • Page 7: Dimensions And Specifications, Gi 3.5/5.0 Wok

    DIMENSIONS AND SPECIFICATIONS, GI 3.5/5.0 WOK 7-7/8" (198mm) 2-5/8"(65mm) 3-7/8" (97mm) removable washable air lter freshair 7-7/8"(198mm) 6'cordandplug 2-3/4"(70mm) (208/240volt,60cycleunitsonly) 8-3/8"(210mm) viewA:exhaust WOK-ceramicshell 5-7/8" (144mm) exhaust 15"(380mm) PLUG CONFIGURATIONS: Electrical Model Plug Characteristics 208V/60Hz/1Ø GIWOK-3.5 240V/60Hz/1Ø GIWOK-5.0 208V/60Hz/3Ø Electrical Loading: Model Watts 208/60/1...
  • Page 8: Operation And Control

    Purpose of induction cookers Features include: • Simple operation with rotary switch The Garland induction unit cookers are especially suitable as cookers in the kitchen and for the preparation of meals • Compact powerful electronics enable flat construction on the table. A cooker can be used for cooking, warming up, and safe operation keeping warm, flambéing, roasting, etc.
  • Page 9: Location

    INSTALLATION Location Clearances The Cooker must always be set up on a clean and even There is a minimum clearance of 1.5” (40mm) from the back surface (Table, base etc.) The Cooker stands on non-slip wall. rubber pads and is not permanently installed and does not This induction unit is equipped with an air cooling system.
  • Page 10: Operation

    OPERATION Function Test Make sure the knob is in the “OFF” position. Remove all objects from the glass ceramic cooking zone, Before carrying out function checks, the operator must know verify if this area is neither cracked not broken. Don’t how to operate the cooker.
  • Page 11: Heating

    (0-10 for GUI2.5). We have designed the units such Energy transfer will be stopped. The induction unit must be that the range from 1-9 (1-7 on GIU2.5) controls the heat restarted after it has cooled down. from about 5% to 50% of total power, giving a great range of simmer control.
  • Page 12: Safety Concerns

    SAFETY CONCERNS Description Of Danger Signs 1. The heating area is warmed up from the heat of the pan. To avoid injuries (burning) do not touch the heating area. This symbol identifies the safety 2. To Avoid overheating of pans by means of evaporating information which may cause the contents, don’t heat up pans unattended.
  • Page 13: Trouble Shooting

    TROUBLE SHOOTING CAUTION Do not open the cooker, dangerous electric Stop any actions if the heating area (Ceran plate) is cracked voltage inside. or broken, the induction cooker must be switched off and disconnected from the electric supply. Don’t touch any parts The cookers may only be opened by authorized service inside the cooker.
  • Page 14: Trouble Shooting Guide

    TROUBLE SHOOTING Continued Trouble Shooting Guide Action to take through operator or Fault Possible Cause operating personnel No heating indicator operation is off No electrical supply Check if the electrical supply (cable (dark) plugged in the wall socket), check preliminary fuses Control knob in OFF - position Turn control knob ON Pan too small (bottom diameter less...
  • Page 15: Cleaning And Servicing

    TROUBLE SHOOTING Continued Action to take through operator or Fault Possible Cause operating personnel After a longer permanent operating Coil overheated, cooking area too hot Switch cooker off, remove pan and wait time, the heating switches off and on until the cooking area has cooled off Empty pan within minutes Pan with overheated oil...

This manual is also suitable for:

Giu3.5 dualGiu5.0 dualGiwok3.5Giwok5.0

Table of Contents