General Information; Uncrating; Statutory Regulations; Rating Plate - Garland E22 series Installation Manual

E22 series; e24 series; e18 series; e20 series electric units
Table of Contents

Advertisement

GENERAL INFORMATION

Uncrating

Carefully remove the units from the carton.
Remove all packing material from the units. On stainless steel
and brushed chrome units, the protective material covering
the stainless steel and brushed chrome should be removed.

Statutory Regulations

The installation and connection should comply with current
codes in Canada – The Canadian electrical code part 1 and /
or local codes. In USA – The National Electrical Code ANSI /
NFPA – Current Edition, and include
1. Switch panel size

INSTALLATION

E22 Series Installation Of Banking Plates

All units may be installed independently or banked with
other E22 or G22 Series equipment. To ensure a matching
and permanent fit between units, two banking plates are
available for each unit to be installed. One at the front and
one at the rear of each two units being banked together.
(If 2-1/2" (64mm) legs are supplied with the unit, discard
leveling bolts and replace with the 2-1/2" (64mm) legs.
1. Level each unit by adjustment of leveling bolts or legs.
Use a spirit level and level unit four ways; across front and
back and down left and right edges. Level all other units
to the first unit.
Note: Griddles may not rest evenly on the unit body if
units are not leveled.
2. Remove sheet metal screws at rear of unit.
3. Attach one banking plate in position at rear by placing
the 1/4" (6 mm) diameter holes in the banking plate
over the screw holes in the rear of units and fasten by
replacing the sheet metal screws removed in Step 2.
4. Push units into position on counter top or back bar.
Page 4
2. Overload protection
3. Wire type
4. Wire size
5. Temperature limitations of the wires
6. Method of connection (Cable, Conduit, etc.)

Rating Plate

Ensure that the electrical supply conforms with the electrical
characteristics shown on the rating plate.
For serial plate location (showing voltage and loading), wall
clearances and required temperate ratings for supply cable,
refer to the section for the model being installed.
5. Remove lower front panels, by removing the acorn nuts
on each side of the panel. NOTE: CARE SHOULD BE TAKEN
WHEN REMOVING LOWER FRONT PANEL, SO THAT THE
WIRES ARE NOT DISENGAGED FROM THE SWITCHES OR
CONTROLS.
6. Place the second banking plate in position so that the
5/8" (16mm) diameter Holes in the banking plate fit
over the lower front panel mounting bolts, with the 1/4"
(6mm) diameter holes in the banking plate at the bottom.
7. Secure the banking plate to both units, with the sheet
metal screws provided with the banking plates.
8. Replace and secure the lower front panels

E24 Series Installation of Banking Plates

All units may be installed independently or banked with
other E24 or G24 Series equipment. To ensure a matching
and permanent fit between units, a front banking plate is
supplied with each unit. If 2 1/2"(64 mm) legs are supplied
with nit, discard leveling bolts and replace with 2 1/2"
(64 mm) legs.
Part # P66 (01/25/08)