GENERAL INSTALLATION

Introduction

The Garland EDU series 230V and 240V complies with
the essential requirement of the directives 73/23/EEC,
89/336EEC, 93/68/EEC and the standards; EN60335, IEC529,
EN5501, eN6100-4-A, ENV502404, EN61000-4-4, ENV50142,
IEC1000-4-11, ENV50141. Also complies with the latest
edition of NSF#4.

Safety

This manual pertains to the EDU series counter equipment.
The reader/operator must interpret its contents to applicable
needs. If there is any question of interpretation of any
literature, please contact your authorized service agency or
our customer service department at the phone number in
the information pamphlet.
A qualified person must make the installation of these
products in accordance with local codes.
Always follow these safety precautions when operating these
appliances.
These units must only be operated by qualified persons. DO
NOT operate with out reading this manual.
DO NOT operate the appliance unless all service and access
panels are in place and fastened properly.
DO NOT attempt to repair or place any part of these
appliances unless all main power supplies have been
disconnected.
WARNING
To avoid personal injury; use extreme caution in setting up,
operating and cleaning these appliances to avoid coming
in contact with hot surfaces. Suitable protective clothing
should be worn or proper utensils used to prevent the risk of
burns.
Note all warning labels and marking on the appliance, which
call attention to further dangers and necessary precautions.
THESE APPLIANCES SHOULD NOT BE CLEANED WITH A
WATER JET.

Ventilation

The area in which the appliance is installed must be
adequately ventilated to provide air for removal of steam,
heat generated by the appliance etc. the use of mechanical
extract system should be considered and conform to local
codes.
Part # 4521353 (06/17/09)

Electrical Supply

Before attempting the electrical connection, the serial plate
should be checked to ensure that the equipment's electrical
characteristics agree.
The supply terminal block is accessible from the font. The
electrical supply must be adequate for the voltage, phase
and current marked on the serial plate.
Note: a means of disconnection from the supply having
a contact separation of at least 3 mm (0.12") must be
incorporated in the fixed wiring.
This equipment is intended to be installed with fixed
permanent wiring.
Warning: This appliance must be earthed .
Single and three-phase connection:
Unless otherwise noted, all appliances are shipped from
the factory for three phase connection. A wiring diagram is
attached to the rear each appliance. Visually check all the
electrical connections. The appliance is wired at the factory
as specified on the order. If it is necessary to change the
phasing, refer to the wiring diagram.

Installation Of Banking Plates

All units may be installed independently or banked with
other ED or GD series equipment. To ensure a matching
and permanent fit between units, two banking plates are
available for each unit to be installed. One at the front and
one at the rear of each two units being banked together.
If optional 4" (102mm) legs are supplied with unit, discard
leveling bolts and replace with legs.
REAR VIEW