Heat & Glo ST-42TVFL-IPI Owner's Manual page 21

Hide thumbs Also See for ST-42TVFL-IPI:
Table of Contents

Advertisement

Wall Switch Installation for Fan (Optional)
If the box is being wired to a wall mounted switch for use
with a fan (See Figure 11):
• The power supply for the appliance must be brought
into a switch box.
• The power can then be supplied from the switch box to
the appliance using a minimum of 14-3 with ground
wire.
• At the switch box connect the black (hot) wire and red
(switch leg) wire to the wall switch as shown.
• At the appliance connect the black (hot), white (neutral)
and green (ground) wires to the junction box as shown.
• Add a 1/4 inch insulated female connector to the red
(switch leg) wire, route it through the knockout in the
face of the junction box, and connect to the top fan
switch connector (1/4 inch male) as shown.
Figure 11. Junction Box Wired to Wall Switch
MINIMUM 14-3 AWG
WITH GROUND
JUNCTION BOX
Red
Heat & Glo • ST-42TVFL-IPI • 455-902 Rev. C • 12/07
Red
Black
White
Green
SWITCH BOX
SWITCH
Black
White
Green
POWER
SUPPLY WIRES
21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents