Top Vent - Vertical Termination
MODEL
FLUE TERMINATION APPROVALS
350TRSI-AUF
350TRSILP-AUF
This model is approved to use DVP or SLP Series flue
pipe components. A DVP-TVHW or SLP-TVHW vertical
Termination Cap must be used to terminate flue systems
in a vertical position.
Approved flue system components are labeled for identifi-
cation. NO OTHER FLUE SYSTEMS OR COMPONENTS
MAY BE USED. Detailed installation instructions are in-
cluded with each flue termination kit and should be used
in conjunction with this manual.
WARNING! Risk of Fire! This gas appliance and flue
assembly must be flued directly to the outside and must
never be attached to a chimney serving a separate solid
fuel burning appliance. Each gas appliance must use a
separate flue system-common flue systems are prohibited.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specified in
this manual. Overlapping material could ignite and will in-
terfere with proper operation of doors and louvers.
• Horizontal sections 3 in. (76 mm) from the top of the
pipe.
• Horizontal sections 2-1/2 in. (64 mm) at wall shield
firestops.
• Horizontal sections 1 in. (25 mm) from sides and bottom
of the pipe.
• Vertical sections 1 in. (25 mm) on all sides of pipe.
Failure to keep insulation or other material away from vent
pipe may cause over heating and fire.
For alternative installations, other than depicted, contact
your dealer for further information.
30
SLP-TVHW, DVP-TVHW
Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. R • 2/13
Straight Up Vertical Flue System
Figure 7.7 shows straight up vertical flue system approved
for use on this model.
If the heater installation requires a vertical flue
exceeding 14-3/4 in. (4.5 m) above the unit
with no horizontal flue or elbows a vertical flue
restrictor must be installed (see Figure 7.7).
V
MAX. RUN
36 ft.
(10.97 m)
Figure 7.7
RESTRICTOR
PLATE
Figure 7.8
CAP
V