12
12
Accessories
A. Gas Log/Lighter Provision
WARNING! Fire and/or Asphyxiation Risk! Use with
solid wood fuel or decorative gas appliance only. Gas fi re
generates fumes.
•
DO NOT install unvented gas logs
•
Damper must be locked fully open when gas logs are
installed
A certifi ed gas log lighter or decorative gas log set can be
installed in this fi replace.
•
Maximum input is 100,000 BTU/hr.
•
Decorative gas appliance must be certifi ed to ANSI
Z21.60 "Standard for Decorative Gas Appliances for
Installation in Vented Fireplaces".
•
Must be installed in accordance with the National Fuel
Gas Code, ANSI Z223.1.
•
A gas log set must incorporate a gas shutoff.
•
Gas Log set requires the damper to be locked fully
open.
•
A listed automatic damper system with safety interlock
may be used in this fi replace with only compatible,
listed gas log sets. See damper system manufacturer's
insturctions.
•
Knockouts are provided on both sides of the fi replace
and in refractories for 1/2 in. (13 mm) iron pipe.
•
Seal refractory around pipe with fi replace mortar or a
non-combustible sealant.
Firebox
Refractory
Seal with
fireplace mortar
or non-combust-
ible sealant
Gas Line
Repack
Insulation
Knockout
4 in.
(102 mm)
Figure 12.1 Gas Line Installation
42
Outer Shell
of Fireplace
Maintain air clearance
to combustibles.
Combustible
Materials
1 1/2 in. (38 mm)
air space around
pipe
Gas Line
Combustible materials
may be located at zero
clearance to gas line
beyond 4 in. (102 mm)
from fireplace side.
Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08
B. Wood Burning Inserts
WARNING! Risk of Fire! Improper installation of wood in-
serts may cause fi replace or chimney system to overheat.
If a wood burning insert is being installed in this fi replace,
Hearth & Home Technologies recommends full reline of
the chimney.
•
Cooling air openings at the top of the chimney must not
be obstructed in any manner.
•
Hearth & Home Technologies recommends securing the
reline at the top of the fl ue and using the cap certifi ed for
use with this fi replace system.