B. Facing Material
WARNING
Fire Risk
Do NOT obstruct air inlet or outlet grilles.
Do NOT modify grilles.
•
Modifying or covering grilles could cause
temperature rise and fi re hazard.
Finishing materials must not interfere with:
•
Air fl ow through grilles or louvers.
•
Operation of louvers or doors.
•
Access for service.
Finish wall material
may be combustible,
top & sides.
0 mm.
Sealant Material
Figure 7.2
Non-combustible Facing Diagram
12
Upper front can be covered
with non-combustible material
or removed and replaced with
non-combustible material.
0 mm.
Heat & Glo Lifestyle Collection • Dakota-AU• 4036-914 Rev B • 06/07
Fire Risk
Finish all edges and fronts to clearances and
specifi cations listed in manual.
•
Metal fireplace front may be covered with non-
combustible material only.
•
Do NOT overlap combustible materials onto fi replace
front.
•
Install combustible materials up to specifi ed clearances
on top front and side edges.
•
Seal joints between the fi nished wall and fi replace top
and sides using only a 150° C minimum sealant.
0 mm.
WARNING